Trouble Resolution

Table 4-1. LANVIEW LED Signals (Continued)

LED

Color

Condition

 

 

 

 

 

 

Ports

off

Port enabled but not linked.

 

 

 

 

Green

Port enabled and linked.

 

 

 

 

Red

Port disabled (or set to Ring Out) and not linked.

 

 

 

 

blinking

Ring Speed Fault -OR- Port linked but disabled.

 

Red

 

 

 

 

4.2 Trouble Resolution

If this section does not guide the user to a solution, please contact Cabletron Systems Technical Support (see Section 1.4, Getting Help.)

Loss Of Power

If the STHI is having power problems, check the power delivery system (power cable, power outlet, circuit breaker, fuse).

Failure to Link on Enabled Port

1

2

Check that the Token Ring devices at either end of the cable are powered-up.

Verify that the network cable’s connectors have the proper pinouts. Refer to Section 2.2.2, TCU and COM Ports.

Check the cable for continuity. A variety of tools are available for this test, depending on the media being used.

Check that the cables meet specifications for dB loss as described in Appendix A, TPIM Specifications.

Ring Speed Fault

3

The network device being linked at this port is operating at a ring speed different from the STHI hub’s currently set ring speed. Set the two devices to the same speed.

Page 4-2

Page 33
Image 33
Cabletron Systems STHI manual Trouble Resolution, Loss Of Power, Failure to Link on Enabled Port, Ring Speed Fault