Cabletron Systems STHI manual B.3 Single Mode and Multimode Fiber Optic Cabling

Models: STHI

1 77
Download 77 pages 20.09 Kb
Page 77
Image 77
Single Mode and Multimode Fiber Optic Cabling

Single Mode and Multimode Fiber Optic Cabling

Table B-4. STP Maximum Lengths

IBM

Max. Lobe Length

Max. Drive Distance

 

 

 

 

Type

4 Mbps

16 Mbps

4 Mbps

16 Mbps

 

 

 

 

 

 

 

 

 

 

 

1 & 2

200 meters

100 meters

770 meters

346 meters

 

(660 feet)

(300 feet)

(2525 feet)

(1138 feet)

 

 

 

 

 

6 & 9

30 meters

30 meters

513 meters

230 meters

 

(99 feet)

(99 feet)

(1683 feet)

(755 feet)

 

 

 

 

 

B.3 Single Mode and Multimode Fiber Optic Cabling

TPIM models F2 and F3 support multimode and singlemode fiber optic cable respectively. Table B-5 below defines total signal attenuation tolerances for fiber cabling. Both media have a typical constant attenuation rate per km of fiber cable and each connector on the cable system contributes significant additional attenuation. Maximum drive distances define maximum allowable cable length.

Table B-5. Signal Tolerances for Fiber Optic Cable

 

 

Total

Maximum

 

 

Allowable

 

Cable Type

Drive Distance

 

Attenuation

 

 

 

 

 

 

 

Multimode

50/125 m

13.0 dB or less

2 km (2187.2 yards)

 

 

 

62.5/125 m

16.0 dB or less

 

 

 

 

 

 

 

 

100/140 m

19.0 dB or less

 

 

 

 

 

 

Typical Signal Attenuation Rate: 2.5 dB/km.

 

 

 

 

Single

8/125-12/125 m

10.0 dB or less

10 km (10936.0 yards).

 

 

 

Typical Signal Attenuation Rate: 0.5 dB/km.

 

 

 

 

NOTE

The attenuation values shown in Table B-5 include the attenuation attributable to cables, connectors, patch panels, and reflection losses due to impedance mismatches in the segment.

Page B-5