Before You Use the Product
Item | Pin No. | Pin name | Input/ | Signal direction | Notes | |
Output | ||||||
External lighting | A8 | Light_ON/OFF- | Output | Current input | External lighting switch | |
control signal | 50V/200mA (max.) | |||||
|
|
|
| |||
|
|
|
|
|
| |
| B8 | Light_ON/OFF+ | Output | Current output | External lighting switch | |
| 50V/200mA (max.) | |||||
|
|
|
|
| ||
Alarm control | A9 | Alarm_- | Output | Current input | Alarm control 50V/ | |
signal | 200mA (max.) | |||||
|
|
|
| |||
|
|
|
|
|
| |
| B9 | Alarm_+ | Output | Current output | Alarm control 50V/ | |
| 200mA (max.) | |||||
|
|
|
|
| ||
External sensor | A10 | Sensor_- | Input | Current input | GND | |
input |
|
|
|
|
| |
B10 | Sensor_+ | Input | Current output | |||
| ||||||
| protected | |||||
|
|
|
|
| ||
|
|
|
|
|
|
External Device I/O Terminals
External device input terminals
These comprise 2 sensor terminals (positive (+) and negative
External device output terminals
These comprise ON and OFF terminals for the alarm and light terminals, with equivalent terminals in both directions for the respective combinations. The two terminals can be switched between conductive and resistive states using the internal controller. In addition, an optical connector is used in the output terminal and is separate from the internal circuits in the camera.
The load connected to the output terminal should be within the following ratings: Rated values between output terminals
Max. DC voltage: 50V
Continuous load current: 120 mA
ENGLISH
17