Carrier 42V, 42C, 42D specifications A42-4129, 42SGS Furred-InSlave Stack Dimensions

Models: 42V 42D 42S 42C

1 72
Download 72 pages 52.3 Kb
Page 35
Image 35
A42-4129

LEGEND

CR — Cold Water Return

CS — Cold Water Supply

D — Drain

HR — Hot Water Return

HS — Hot Water Supply

R — Return

S — Supply

ITEM

DESCRIPTION

QTY

1

Electrical Knockouts

1

2

Strip Heater** (Optional)

1

3

Limit Switch**†† (Optional)

1

4

1/2-in. Isolation Ball Valves**

2/4

5

Coil Stub Outs

2/4

6

Shipping Brace

2/4

7

Flexible Drain Tube/P-Trap

1

8

Coil 1/2-in. OD Copper Tube

1

9

Filter, Throwaway, 1-in.**

1

10

Return Air Opening

1

11

Air Vent, Manual

1

12

Knockout (For Optional Remote Mounting)

2

13

Molex Connector for Field-Installed Stat

1

14

Control Box

1

15

Drain Pan

1

16

Return Air Blockoff Panel (Optional)

1

17

Blower

1

18

Motor, 3-Speed, PSC, with Quick Connect

1

19

Access Panel (Control Box)

1

20

Control Opening (Surface Mount Thermostat)

1

21

Duct Collar, 1/2-in. Extension (Typical)

1/2/3

22

Supply Air Opening(s)

1/2/3

**Factory-Installed. ††Field-Installed.

*Drawing provided for reference only. Dimensions may vary with options ordered.

NOTES:

1.Units are fabricated of 18-gage galvanized steel with a 16-gage galvanized fan deck.

2.All risers are insulated with 1/2-in. closed cell insulation.

3.

Thermostats shipped loose for field connection.

 

 

 

 

 

 

 

A42-4129

4.

Risers are piped to coil with valves as specified.

 

 

 

 

 

 

 

5.

Blower, motor, valves, coil, and filter are accessible through the return air opening.

 

 

 

 

 

6.

Unit and control box are insulated with 1/2-in. coated fiberglass insulation.

 

 

 

 

 

 

7.

Riser length = [(floor to floor) +2 in.], maximum riser length = 115 inches.

 

 

 

 

 

 

8.

Maximum riser size is 21/2-in. diameter. If larger sizes are required, please consult the factory.

 

 

 

9.

Expansion loops in hot water heating circuits as required.

 

 

 

 

 

 

 

 

10.

A 9-in. x 21/4-in. slot is provided in the inside back panel for coil connection penetration to permit expansion

 

 

and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot.

 

11.

Drawing is pictorial (see unit arrangements for actual supply and return air orientation).

 

 

 

12.

All dimensions are in inches.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

NOM

 

 

 

 

 

DIMENSIONS (in.)

 

 

 

 

 

UNIT

SIZE

AIRFLOW

Single Supply

Double Supply

 

Top Supply

E

G

 

H

I

WEIGHT†

(cfm)

A

 

B

A

 

B

 

C

D

 

(lb)

 

 

 

 

 

 

 

 

 

 

 

 

03

 

300

14

 

8

14

 

6

 

14

10

17

11/2

 

11/2

14

162

04

 

400

14

 

12

14

 

6

 

14

10

17

11/2

 

11/2

14

203

06

 

600

18

 

10

18

 

6

 

16

12

20

1

 

2

18

216

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08

 

800

18

 

12

18

 

6

 

16

12

20

1

 

2

18

234

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

1000

 

22

 

8

 

18

16

24

1

 

3

22

252

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

1200

 

22

 

8

 

18

16

24

1

 

3

22

275

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

†Unit weights are based on dry coils and minimum rows. Weights exclude packaging, valves, and other components.

Fig. 32 — 42SGS Furred-In Slave Stack Dimensions

35

Page 35
Image 35
Carrier 42V, 42C, 42D specifications A42-4129, 42SGS Furred-InSlave Stack Dimensions