LEGEND
CR — Cold Water Return
CS — Cold Water Supply
D — Drain
HR — Hot Water Return
HS — Hot Water Supply
R — Return
S — Supply
ITEM | DESCRIPTION | QTY |
1 | Electrical Knockouts | 1 |
2 | Strip Heater** (Optional) | 1 |
3 | Limit Switch**†† (Optional) | 1 |
4 | 2/4 | |
5 | Coil Stub Outs | 2/4 |
6 | Shipping Brace | 2/4 |
7 | Flexible Drain | 1 |
8 | Coil | 1 |
9 | Filter, Throwaway, | 1 |
10 | Return Air Opening | 1 |
11 | Air Vent, Manual | 1 |
12 | Knockout (For Optional Remote Mounting) | 2 |
13 | Molex Connector for | 1 |
14 | Control Box | 1 |
15 | Drain Pan | 1 |
16 | Return Air Blockoff Panel (Optional) | 1 |
17 | Blower | 1 |
18 | Motor, | 1 |
19 | Access Panel (Control Box) | 1 |
20 | Control Opening (Surface Mount Thermostat) | 1 |
21 | Duct Collar, | 1/2/3 |
22 | Supply Air Opening(s) | 1/2/3 |
*Drawing provided for reference only. Dimensions may vary with options ordered.
NOTES:
1.Units are fabricated of
2.All risers are insulated with
3. | Thermostats shipped loose for field connection. |
|
|
|
|
|
|
|
| ||||||||
4. | Risers are piped to coil with valves as specified. |
|
|
|
|
|
|
| |||||||||
5. | Blower, motor, valves, coil, and filter are accessible through the return air opening. |
|
|
|
|
| |||||||||||
6. | Unit and control box are insulated with |
|
|
|
|
|
| ||||||||||
7. | Riser length = [(floor to floor) +2 in.], maximum riser length = 115 inches. |
|
|
|
|
|
| ||||||||||
8. | Maximum riser size is |
|
|
| |||||||||||||
9. | Expansion loops in hot water heating circuits as required. |
|
|
|
|
|
|
|
| ||||||||
10. | A |
| |||||||||||||||
| and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot. |
| |||||||||||||||
11. | Drawing is pictorial (see unit arrangements for actual supply and return air orientation). |
|
|
| |||||||||||||
12. | All dimensions are in inches. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
UNIT | NOM |
|
|
|
|
| DIMENSIONS (in.) |
|
|
|
|
| UNIT | ||||
SIZE | AIRFLOW | Single Supply | Double Supply |
| Top Supply | E | G |
| H | I | WEIGHT† | ||||||
(cfm) | A |
| B | A |
| B |
| C | D |
| (lb) | ||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||
03 |
| 300 | 14 |
| 8 | 14 |
| 6 |
| 14 | 10 | 17 | 11/2 |
| 11/2 | 14 | 162 |
04 |
| 400 | 14 |
| 12 | 14 |
| 6 |
| 14 | 10 | 17 | 11/2 |
| 11/2 | 14 | 203 |
06 |
| 600 | 18 |
| 10 | 18 |
| 6 |
| 16 | 12 | 20 | 1 |
| 2 | 18 | 216 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
08 |
| 800 | 18 |
| 12 | 18 |
| 6 |
| 16 | 12 | 20 | 1 |
| 2 | 18 | 234 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 |
| 1000 | — |
| — | 22 |
| 8 |
| 18 | 16 | 24 | 1 |
| 3 | 22 | 252 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12 |
| 1200 | — |
| — | 22 |
| 8 |
| 18 | 16 | 24 | 1 |
| 3 | 22 | 275 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
†Unit weights are based on dry coils and minimum rows. Weights exclude packaging, valves, and other components.
Fig. 32 — 42SGS Furred-In Slave Stack Dimensions