Troubleshooting
Specification
Install
Error codes
Configuring the Controller
Connecting the Controller
Array Problems
Resetting Array Statistics
To set up LUN zoning
Restoring Default Settings
Page 159
Image 159
Page 158
Page 160
Page 159
Image 159
Page 158
Page 160
Contents
User’s Guide
Page
Technical Support
Copyright
Trademarks
Changes
Canadian Compliance Statement
Contents
Hardware Installation
Monitoring System Status
Managing Disk Drives and Enclosures
Glossary
K-Series User’s Guide Viii
About This Guide
Introduction
Motherboard Ultra2 Scsi Channels G-Series
Product Features
Conventions
Motherboard CPU Subsystem G-Series
Battery Interface G-Series
Hardware Configuration and Management Support G-Series
Motherboard Disk Cache G-Series
Motherboard Ultra2 Scsi Channels K-Series
Onboard Connectors G-Series
Daughterboard G-Series
Motherboard CPU Subsystem K-Series
Motherboard Disk Cache K-Series
Integrated Battery Backup and Interface K-Series
Fibre Channel Connection K-Series
Fibre Channel Features
Hardware Configuration and Management Support K-Series
Onboard Connectors K-Series
Electrical G-Series
Specifications
Specifications
Physical G-Series
Environmental G-Series
3shows the environmental specifications of the controllers
Battery G-Series
Electrical K-Series
Physical K-Series
Environmental K-Series
7shows the environmental specifications of the controllers
Battery K-Series
Reference Documents
External Documents
Chaparral Documents
K-Series User’s Guide
Connecting to the Fibre Channel Port
Hardware Installation
Connecting the Controller
Connecting to the Scsi Port
To connect to the Fibre Channel port
Connecting to the RS-232 Port
To connect to the RS-232 port
K-Series User’s Guide
Setting Value
Accessing the Disk Array Administrator Software
SettingValue
Do this
Navigating the Disk Array Administrator Software
Disk Array Administrator Menu Tree
Changing the Screen Display
Select Function
Menu tree
K-Series User’s Guide
Creating and Managing Arrays
Creating Arrays
Minimum Maximum RAID Level No. Drives
To create an array
Creating and Managing Arrays
RAID Type screen displays
Scsi ID
K-Series User’s Guide
Creating and Managing Arrays
Viewing Array Status
Managing Arrays
To view the status of an array
To view the array statistics
Viewing Array Statistics
Creating and Managing Arrays
To reset array statistics
Resetting Array Statistics
To view drive status
Viewing Drive Status
Stopping the Array Initialization Process
To stop the array initialization process
Select Abort Initialization and press Enter
To verify an array
Verifying an Array
To view verification status
Viewing Verification Status
To stop the verification process
Reconstructing an Array
RAID Level Number of Drives You Can Add
Expanding Array Capacity
To expand an array
To view expand status
Viewing Expand Status
To change the array LUN
Changing the Array LUN
Changing the Array Name
Trusting an Array
To change the array name
To trust an array
To delete an array
Deleting an Array
Displaying the Event Log
Monitoring System Status
Viewing One Event at a Time
Viewing the Most Recent Event
Select View Event Log and press Enter
To display one event at a time
To capture the event log file
Viewing a Whole Screen of Events
Capturing the Event Log File
To display a whole screen of events
Group Field What displays
Displaying Hardware and Configuration Information
LUN
Capi
SEP
To display hardware information only
Press Esc to return to the Utilities Menu
To display hardware and configuration information
Displaying Overall Statistics
To access the general array statistics
To access the read/write histogram
To reset overall statistics
Resetting Overall Statistics
Managing Dedicated Spares
Managing Spares
To add a dedicated spare
Adding a Dedicated Spare
Enabling Dynamic Spares
Deleting a Dedicated Spare
To delete a dedicated spare drive
To enable dynamic spares
Managing the Spare Pool
Adding a Spare to the Spare Pool
To add a pool spare
Deleting a Spare from the Spare Pool
To delete a spare from the spare pool
Select Delete Pool Spare and press Enter
Displaying the Spare Pool
To display the spare pool
Select Display Pool Spares and press Enter
K-Series User’s Guide
Rebooting the Controller
Configuring the Controller
Changing the Date and Time
To shut down and restart the controller
To set the controller’s date
To set the controller’s time
Understanding LUNs
Configuring the Controller
Changing the Controller’s Target ID and LUN
Do this
To change the controller’s target ID and LUN
Keep the same Loop ID for the channel at all times
To configure the channel
Configuring the Scsi Channels
K-Series User’s Guide
1shows an example of how you can use LUN zoning
Working with LUN Zoning
To view known WWNs
Viewing Known WWNs
Select Display Host List and press Enter
Creating Names Aliases for Server WWNs
To create or change names for WWNs
Select Add or Name Host and press Enter
To set up LUN zoning
Configuring LUN Zoning
K-Series User’s Guide
To change the sample rate
Changing the Sample Rate
Alarm threshold What to do when the alarm sounds
Changing the Alarm Mute Setting
Software
To enable or disable the alarm
To lock the cache setting
Locking the Cache Setting
To change the battery setting
Enabling and Disabling the Battery
Changing the Utility Priority
Rescanning All Channels
To change Utility priority
Select Utility Priority and press Enter
To rescan all channels
Pausing I/O
To pause I/O
Restoring Default Settings
Upgrading the Controller’s Firmware
To restore the default settings
Select Restore Defaults and press Enter
Upgrading Firmware
See Chaparral Technical Support on
To upgrade the controller’s firmware
K-Series User’s Guide
Managing Disk Drives
Managing Disk Drives and Enclosures
Displaying All Drives
Displaying Drive Information
To display all drives
To view drive status
Clearing Metadata from a Drive
To change the write-back cache setting
Enabling and Disabling Write-back Cache
To clear metadata from a drive
K-Series User’s Guide
To display disk cache status
Displaying Disk Cache Status
Enabling and Disabling Smart Changes
To enable or disable Smart changes
To blink a drive
Blinking a Drive LED
To take down a drive
Taking Down a Drive
Testing a Drive
Managing SAF-TE Enclosures
To test a drive
To change the SEP LUN
Changing the SEP LUN
Do this
To change the SEP settings
Changing the Additional SEP Settings
Managing Disk Drives and Enclosures
K-Series User’s Guide
Chaparral Technical Support
Troubleshooting
Terminal Emulator and COM Port Problems
Problem Screen continuously puts out garbage characters
Array Problems
Problem Screen is updated, but won’t respond to keystrokes
Problem Array is much smaller than it should be
Host Scsi Channel Problems
Problem The host Scsi Bios scan hangs
To change the backoff percentage
Problems During Bootup
Device Scsi Channel Problems
Problem The system hangs at CTsrv starting
Controller Problems
Problem Controller failed the onboard memory test
Problem One of the Post diagnostic test failed
Problem The controller reports a Battery error
Problem The controller reports a Sdram memory error
Critical
Event Definition Recommended Action
Warn
Errors
Disk Errors
Using the Loader Diagnostics Menu
Using the Loader Utility Menu
Understanding Scsi Errors
Descriptions
Sense Key Description
Disk Channel Errors
Error Code Description
Voltage and Temperature Errors and Warnings
K-Series User’s Guide
Array Basics
Array Types
RAID 0 Striped Disks
RAID
RAID 1, RAID 1/O Mirrored Disks
Array Basics
Volume Sets
Comparing RAID Levels
Min No Description Strengths Weaknesses Level Drives
RAID 3 RAID
Mixing Disks on Different RAID Controller Channels
Glossary
K-Series User’s Guide
Glossary
K-Series User’s Guide
Glossary
K-Series User’s Guide
Index
K-Series User’s Guide
Index
K-Series User’s Guide
Index
Scsi ID
Index
K-Series User’s Guide