Cisco Systems 15310-MA manual ML-100T-8 Card, CE-MR-6 Card-Level Indicators

Models: 15310-MA

1 352
Download 352 pages 59.1 Kb
Page 70
Image 70

Chapter 2 Card Reference

ML-100T-8 Card

2.4.1 CE-MR-6 Card-Level Indicators

The CE-MR-6 card faceplate has two card-level LED indicators, described in Table 2-6.

Table 2-6 CE-MR-6 Card-Level Indicators

Card-Level LEDs

Description

 

 

FAIL LED (Red)

The red FAIL LED indicates that the card processor is not ready or that a

 

catastrophic software failure occurred on the CE-MR-6 card. As part of the

 

boot sequence, the FAIL LED blinks until the software deems the card

 

operational, then it turns off.

 

 

ACT/STBY LED

The ACT/STBY LED provides the operational status of the CE-MR-6. When

(Green)

the ACT/STBY LED is green, it indicates that the CE-MR-6 card is active

 

and the software is operational; otherwise, it is off.

 

 

2.4.2 CE-MR-6 Port-Level Indicators

The CE-MR-6 card has an LED for each of the six ports, described in Table 2-7.

Table 2-7 CE-MR-6 Port-Level Indicators

Port-Level Indicators

Description

 

 

Off

No link exists to the Ethernet port.

 

 

Steady amber

A link exists to the Ethernet port, but traffic flow is inhibited. For

 

example, a lack of circuit setup, an error on the line, or a disabled port

 

might inhibit traffic flow.

 

 

Solid green

A link exists to the Ethernet port, but no traffic is carried on the port.

 

 

Flashing green

A link exists to the Ethernet port, and traffic is carried on the port. The

 

LED flash rate reflects the traffic rate for that port.

 

 

2.5 ML-100T-8 Card

This section describes the features and functions of the Layer 2 10/100 Ethernet card, the ML-100T-8. The card is compatible with the ONS 15310-MA SDH.

Note The ML-100T-8 card with PID 15310-ML-100T-8 is not compatible with the ONS 15310-MA SDH. 15310-P-ML-100T-8 is compatible with the ONS 15310-MA SDH shelf assembly. If you install a 15310-ML-100T-8 in an ONS 15310-MA SDH shelf assembly, you will receive a mismatched equipment alarm (mismatchofEquipment). You can view the PID under the node view Inventory tab in CTC.

Cisco ONS 15310-MA SDH Reference Manual, Release 9.1 and Release 9.2

2-12

78-19417-01

 

 

Page 70
Image 70
Cisco Systems 15310-MA manual ML-100T-8 Card, CE-MR-6 Card-Level Indicators, CE-MR-6 Port-Level Indicators