12-19
Cisco ONS 15310-MA SDH Reference Manual, Release 9.1 and Release 9.2
78-19417-01
Chapter 12 SNMP
SNMP Remote Monitoring

12.10.4.4 Row Deletion in alarmTable

To delete a row from the table, the SetRequest PDU should contain an alarmStatus value of 4 (invalid).
A deleted row can be recreated.
Note Entries in the alarmTable are preserved if the SNMP agent is restarted.
12.10.5 Event RMON Group
The event group controls event generation and notification. It consists of two tables: the eventTable,
which is a read-only list of events to be generated, and the logTable, which is a writable set of data
describing a logged event. The ONS 15310-MA SDH implement the logTable as specified in RFC 2819.

12.10.5.1 Event Table

The eventTable is read-only and unprovisionable. The table contains one row for rising alarms and
another row for falling ones. This table has the following restrictions:
The eventType is always log-and-trap (4).
The eventCommunity value is always a zero-length string, indicating that this event causes the trap
to be despatched to all provisioned destinations.
The eventOwner column value is always “monitor.”
The eventStatus column value is always valid(1).

12.10.5.2 Log Table

The logTable is implemented exactly as specified in RFC 2819. The logTable is based upon data that is
cached locally on a controller card. If there is a controller card protection switch, the existing logTable
is cleared and a new one is started on the newly active controller card. The table contains as many rows
as provided by the alarm controller.