A-7
Cisco ONS 15310-MA SDH Reference Manual, Release 9.1 and Release 9.2
78-19417-01
Appendix A Specifications
Card Specifications
C-Temp: 0 to +55 degrees Celsius (32 to 131 degrees Fahrenheit)
Operating humidity: 5 to 85 percent, noncondensing. Operation is guaranteed for 96 hours at 95
percent relative humidity.
Power consumption: 1.10 A, 53 W
Dimensions
Height: 176 mm (6.93 in.)
Width: 34.29 mm (1.35 in.)
Depth: 238.25 mm (9.38 in.)
Weight (not including clam shell): 0.499 kg (1.1 lb)
Caution Do not install CE-100T-8 and ML-100T-8 cards in OSP.
A.2.4 CE-MR-6 Card
The CE-MR-6 card has the following specifications:
Environmental
Operating temperature
I-Temp: -40 to +65 degrees Celsius (-40 to +149 degrees Fahrenheit)
Operating humidity: 5 to 85 percent, noncondensing. Operation is guaranteed for 96 hours at 95
percent relative humidity.
Power consumption: 63.00 W, 1.32 A at -48 V, 214.96 BTU/hr
Dimensions
Height: 176.28 mm (6.94 in.)
Width: 34.29 mm (1.35 in.)
Depth: 236.68 mm (9.318 in.)
Weight (not including clam shell): 0.499 kg (1.1 lb)
A.2.5 E1_21_E3_DS3_3 and E1_63_E3_DS3_3 Cards
The E1_21_E3_DS3_3 and E1_63_E3_DS3_3 cards have the following specifications:
For E1:
Environmental
Operating temperature:
I-Temp: -40 to +65 degrees Celsius
Operating humidity: 5 to 85 percent, noncondensing. Operation is guaranteed for 96 hours at 95
percent relative humidity.
Power consumption:
E1_63_E3_DS3_3: 40.00 W, 0.96 A
E1_21_E3_DS3_3: 27.60 W, 0.70 A