11-17
Cisco ONS 15310-MA SDH Reference Manual, Release 9.1 and Release 9.2
78-19417-01
Chapter 11 Performance Monitoring
Performance Monitoring for Electrical Ports
Figure 11-5 PM Read Points on the E3 Ports
The PM parameters for the E3 ports are listed in Table 11- 4. The parameters are defined in Tab le 1 1-2
on page 11-4.
11.5.3 DS3 Port Performance Monitoring Parameters
Figure 11-6 shows the signal types that support near-end and far-end PM parameters for the DS3 Port.
Figure 11-7 shows where overhead bytes detected on the ASICs produce performance monitoring
parameters for the DS3/E3 Port.
243069
ONS 15310-MA SDH
E3 Card
LIU Mux/Demux ASIC
BTC
ASIC
Cross-Connect
Card STM-N
E3 Side
Low-
Order
Path
Level
SDH Side
LP-EB
LP-BBE
LP-ES
LP-SES
LP-UAS
LP-ESR
LP-SESR
LP-BBER
HP-EB
HP-BBE
HP-ES
HP-SES
HP-UAS
HP-ESR
HP-SESR
HP-BBER
CV-L
ES-L
SES-L
LOSS-L
P-ES
P-SES
P-UAS
P-ESR
P-SESR
PMs read on Mux/Demux ASIC
PMs read on LIU High-
Order
Path
Level
Table 11-4 PM Parameters for the E3 Ports
Line (NE) Path (NE) VC3 Low-End Path (NE/FE) VC4 HP Path (NE/FE)
CV-L
ES-L
SES-L
LOSS-L
ES-P
ESR-P
SES-P
SESR-P
UAS-P
LP-BBE
LP-BBER
LP-EB
LP-ES
LP-ESR
LP-SES
LP-SESR
LP-UAS
HP-BBE
HP-BBER
HP-EB
HP-ES
HP-ESR
HP-SES
HP-SESR
HP-UAS