CF2001P
– 16 –
4004-7715-01
4. Check that the External Panel Controller
appears in the computer screen, and then
display the Tech. Rep. Mode screen. (For
details about displaying the Tech. Rep. Mode
screen, refer to the Service Manual.)
NOTE
If the basic screen does not appear in the
External Panel Controller, turn the printer
off. Restart the External Panel Controller,
and then turn the printer on again.
5. Click [X-Rite Calibration] in the Tech. Rep.
Mode screen.
6. Check the message that appears, and then
click the Start key in the External Panel Con-
troller.
Test patterns are printed for the four colors.
(Cyan, Magenta, Yellow, Black)
NOTE
Since it may take some time to output the
test patterns (about 2 minutes), wait until
printing is finished.
• During printing, do not open the front
door. If the front door is opened, restart
the procedure from step 1.
7. After the test patterns are printed, check that
the message appears, and then click the
Start key in the External Panel Controller.
8. Check that the dialog box appears, set the
selector knob to “B”, and then click [OK] in
the dialog box.
9. Check that the dialog box appears, and then
click [Yes] in the dialog box.
10.When the dialog box appears, the auto-cal
strip can be read. Prepare the auto-cal strip.
C4004P565CA
C4004P597CA
C4004P567CA
Test patterns
C4004U568AA
C4004P569CA
C4004U571AA
C4004P570CA
C4004P572CA
C4004P573CA
NEXTNEXT