Chapter 2 Getting Started

Resetting the IP Camera

To power off the IP camera, take either of these actions:

If the IP camera is receiving PoE, disconnect the network cable

If the IP camera is receiving power through the power adapter, unplug the adapter from the wall or disconnect it from the camera

Resetting the IP Camera

You can reset the IP camera by disassembling it and pressing the Reset button on the camera unit (see Figure 1-2 on page 1-5).

There are various reset types, as described in Table 2-1.

You also can perform some reset operations from the Maintenance window as described in the “Maintenance Window” section on page 3-14.

Table 2-1

Resetting the IP Camera

 

 

 

 

 

Reset Type

 

Procedure

Remarks

 

 

 

 

Reboot.

 

Press and immediately release

This action is equivalent to

 

 

the Reset button.

powering the IP camera down

 

 

 

and then powering it up. Settings

 

 

 

that are configured for the IP

 

 

 

camera are retained.

 

 

 

IP address reset.

Press and hold the Reset button

If DHCP is enabled in your

 

 

for at least 1 second but no more

network, the IP camera obtains

 

 

than 9 seconds.

an IP address from the DHCP

 

 

 

server. Otherwise, after 90

 

 

 

seconds, the IP camera IP

 

 

 

address resets to the default

 

 

 

address of 192.168.0.100. All

 

 

 

other configuration settings are

 

 

 

retained.

 

 

 

 

Factory reset.

 

Press and hold the button for at

Sets all IP camera options to

 

 

least 10 seconds.

their default values. After you

 

 

 

perform this procedure, follow

 

 

 

the steps in the “Performing the

 

 

 

Initial Setup of the IP Camera”

 

 

 

section on page 2-7.

 

 

 

 

Cleaning the IP Camera

To clean and IP camera, follow these guidelines:

To clean components, use a clean, dry, soft cloth to gently wipe the components. Do not use liquid cleaners on the dome assembly, except for cleaners that are designed specifically for optical-grade acrylic.

To clean the lens, use only tissue paper or solution that is designed for high quality optical lenses.

 

Cisco Video Surveillance 2611 IP Dome User Guide

2-12

OL-24128-02

Page 24
Image 24
Cisco Systems CIVIS-IPC-2611 Resetting the IP Camera, Cleaning the IP Camera, Reset Type Procedure Remarks, Section on