Chapter 3 Configuring and Managing the IP Camera

Setup Windows

Table 3-3describes the options in the Advanced Setup window.

Table 3-3 Advanced Setup Window Options

Option

CDP

Description

Enable CDP (Cisco Discovery Protocol)

Check this check box if CDP is enabled in your network and you want the IP camera to send CDP discovery messages.

Bonjour

Enable Bonjour (Cisco Discovery Protocol)

Check this check box if Bonjour is enabled in your network and you want the IP camera to send Bonjour discovery messages.

Bonjour enables the automatic discovery of computers, devices, and services on and IP network.

HTTP/HTTPS

Enable HTTP

Check this check box to enable Internet access to the IP camera through an

Alternative Port

HTTP port other than the default port 80. If you enable this option, enter a

 

port number from 1024 through 65535.

 

If you configure an alternative HTTP port, you must specify the port number

 

in the URL for the IP camera when you access it through an HTTP

 

connection. For example, if the IP address of the IP camera is 192.168.1.100

 

and the alternative HTTP port is 1024, enter this URL for the IP camera:

 

http://192.168.1.100:1024.

 

 

Enable HTTPS

Check this check box to enable Internet access to the IP camera through an

Alternative Port

HTTPS port other than the default port 443. If you enable this option, enter

 

a port number from 1024 through 65535.

 

If you configure an alternative HTTPS port, you must specify the port

 

number in the URL for the IP camera when you access it through an HTTPS

 

connection. For example, if the IP address of the IP camera is 192.168.1.100

 

and the alternative HTTPS port is 1024, enter this URL for the IP camera:

 

https://192.168.1.100:1024.

 

 

RTP/RTSP

 

 

 

RTSP Port

Transmission Control Protocol (TCP) port on which the IP camera receives

 

Real-Time Streaming Protocol (RTSP) commands. You must configure this

 

port to allow third-party devices or software to access video streams from the

 

IP camera.

 

RTSP is a standard for connecting a client to control streaming data

 

(MPEG-4) over the web.

 

Valid values are 554 and 1024 through 65535. The default value is 554.

 

 

RTP Data Port

Universal Data Protocol (UDP) port on which the IP camera transmits

 

Real-Time Transport Protocol (RTP) data.

 

RTP is a standard for transmitting real-time data, such as audio and video, to

 

selected clients.

 

Valid values are 1024 through 65535. The default value is 5000. The default

 

value can be used for multicasting and typically does not need to be changed.

 

 