Cisco Systems IGX 8400 Series manual Observe that the ACTIVE LED on the ARM card is on

Models: IGX 8400 Series

1 52
Download 52 pages 51.44 Kb
Page 36
Image 36
Step 3 Observe that the ACTIVE LED on the ARM card is on.

Making Frame Relay Connections

Step 2 From a control terminal or a Cisco WAN Manager NMS workstation, to the node and enter the addalmslot command followed by the slot number where the ARM is located. This will activate the alarm reporting from the card.

Step 3 Observe that the ACTIVE LED on the ARM card is on.

Step 4 Testing the operation of the alarm outputs requires you to create an alarm and note the resulting alarm output. This test is easy on a node that is not connected to the network but difficult on a node in a fully operational network. The best time to create a major alarm an operational network is during a low traffic period. If you create an alarm, go to Step 5. Otherwise, stop here.

Step 5 Create an alarm by disconnecting a trunk cable from the connector on a back card.

Step 6 Observe that a lit MAJOR LED appears on the front of the ARM.

Step 7 Using a voltage/ohm meter (VOM), make sure continuity exists between pins 16 and 17 and between pins 35 and 36 at the DB-37 connector on the ARI card.

Step 8 Reconnect the cable that was disconnected in Step 5.

Step 9 With the VOM, check that the reading between pins 16 and 17 and pins 35 and 36 are open and the MAJOR LED is not on.

Alarm output connections are made at the DB37 connector on the ARI card. The connector pin assignments with the alarm signal names are listed in Table 3-1.(See Appendix C, “Cabling Summary.”)

Table 3-1

ARI Alarm Connector PinOuts

 

 

 

 

 

Pin No.

Alarm Type

Alarm Name

Alarm Description

 

 

 

 

1

both

CHASSIS

Protective ground

 

 

 

 

3

Network

NWMAJA

Major—normally open contact

 

 

 

 

22

Network

 

Major—normally closed contact

 

 

 

 

4

Network

NWMAJC

Major—common contact

 

 

 

 

10

Node

MNVISA

Minor Visual—normally open contact

 

 

 

 

11

Node

 

Minor Visual—normally closed contact

 

 

 

 

12

Node

MNVISC

Minor Visual—common contact

 

 

 

 

16

Node

MJAUDC

Major Audible—common contact

 

 

 

 

17

Node

MJAUDA

Major Audible—normally open contact

 

 

 

 

23

Network

NWMINA

Minor—normally open contact

 

 

 

 

24

Network

 

Minor—normally closed contact

 

 

 

 

25

Network

NWMINC

Minor—common contact

 

 

 

 

29

Node

NWAUDA

Minor Audible—normally open contact

 

 

 

 

30

Node

 

Minor Audible—normally closed contact

 

 

 

 

31

Node

NWAUDC

Minor Audible—common contact

 

 

 

 

35

Node

MJVISC

Major Visual—common contact

 

 

 

 

36

Node

MJVISA

Major Visual—normally open contact

 

 

 

 

3-36Cisco IGX 8400 Series Installation and Configuration

Page 36
Image 36
Cisco Systems IGX 8400 Series manual Observe that the ACTIVE LED on the ARM card is on