Cisco Systems ME 2400 errdisable recovery cause, gbic-invalid global, on the errdisable recovery

Models: ME 2400

1 88
Download 88 pages 56.61 Kb
Page 55
Image 55
the “Two Twisted-Pair

Chapter 3 Troubleshooting

Diagnosing Problems

Table 3-1 Common Problems and Their Solutions (continued)

Symptom

Possible Cause

Resolution

 

 

 

 

No connectivity

Incorrect or bad cable

 

 

 

These are results of no link at both

 

 

 

ends:

 

 

 

A crossover cable was used

For the correct pinouts and

 

when a straight-through was

 

the proper application of

 

required, or the reverse.

 

crossover instead of

 

 

 

straight-through cables, see

 

 

 

the “Two Twisted-Pair

 

 

 

Cable Pinouts” section on

 

 

 

page B-3.

 

 

Enable the automatic

 

 

 

medium-dependent-

 

 

 

interface crossover

 

 

 

(auto-MDIX) feature.

 

The cable is wired incorrectly.

Replace with a tested good

 

 

 

cable.

 

A crossover or straight-through

For 1000BASE-T

 

cable is wired incorrectly.

 

connections, be sure to use

 

 

 

a twisted four-pair,

 

 

 

Category 5 cable.

 

STP checking for possible

Wait 30 seconds for the port

 

loops. STP is available only on

 

LED to turn green.

 

network node interfaces (NNIs).

 

 

 

 

 

Unreadable characters on the

Incorrect baud rate.

Reset the emulation software to

management console

 

9600 baud.

 

 

 

Amber system LED

Fatal POST error detected.

Contact Cisco Systems.

 

 

 

The switch port is placed in

Bad or non-Cisco-approved SFP

Remove the SFP module from

error-disabled state after SFP

module.

the switch, and replace it with a

module is inserted

 

Cisco-approved module. Use the

 

 

errdisable recovery cause

 

 

gbic-invalid global

 

 

configuration command to

 

 

verify the port status, and enter a

 

 

time interval to recover from the

 

 

error-disabled state.

 

 

See the switch command

 

 

reference guide for information

 

 

on the errdisable recovery

 

 

command.

 

 

 

 

Cisco ME 2400 Ethernet Access Switch Hardware Installation Guide

 

OL-7678-01

3-3

 

 

 

Page 55
Image 55
Cisco Systems ME 2400 errdisable recovery cause, gbic-invalid global, on the errdisable recovery, the “Two Twisted-Pair