Symptom

Chapter 3 Troubleshooting

Diagnosing Problems

Table 3-1describes how to detect and resolve these problems.

Table 3-1 Common Problems and Their Solutions

Symptom

Possible Cause

Resolution

 

 

 

Poor performance or excessive

Duplex autonegotiation mismatch.

See the switch software

errors

 

configuration guide for

 

 

information on identifying

 

 

autonegotiation mismatches.

 

 

 

 

Cabling distance exceeded

 

 

Port statistics show excessive

See the switch software

 

frame check sequence (FCS),

configuration guide for

 

late-collision, or alignment

information on displaying

 

errors.

port statistics.

 

For 10/100BASE-TX

 

 

connections:

 

 

The distance between the

Reduce the cable length to

 

port and the attached device

within the recommended

 

exceeds 328 feet (100

distances.

 

meters).

 

 

If the switch is attached to a

See your repeater

 

repeater, the total distance

documentation for cabling

 

between the two end

guidelines.

 

stations exceeds the cabling

 

 

guidelines.

 

 

For SFP module port

See your SFP module

 

connections:

documentation for cabling

 

The distance between the

guidelines.

 

 

 

SFP module port and the

 

 

attached device exceeds the

 

 

SFP module cabling

 

 

guidelines.

 

 

 

 