4-4Compaq 3000 Series UPS Operation and Reference Guide

Table 4-1

Configuration Parameters/LED Indicators

Parameter

 

Parameter

 

LED 16

 

Explanation

(LED)

 

Name

 

Status

 

 

 

 

 

 

 

 

 

1

 

120/230 Nom

 

On1

 

Nominal utility voltage level is

 

 

 

 

 

 

120/230 VAC.

 

 

 

 

 

 

(Default for R3000, R3000h,

 

 

 

 

 

 

and R3000h-Int)

 

 

 

 

 

 

 

2

 

110/220 Nom

 

On1

 

Nominal utility voltage level is

 

 

 

 

 

 

110/220 VAC.

3

127/240 Nom

On1

 

 

 

10

100/208 Nom

On1

Nominal utility voltage level is 127/240 VAC.

Nominal utility voltage level is 100/208 VAC.

(Default for R3000j and R3000h-NA)

4

Extended

On

UPS will supply utility power if the utility

 

Voltage

 

voltage is within +20% to –35% of the

 

 

 

nominal voltage. If the utility voltage is

 

 

 

outside this range, the UPS will supply

battery power.

(This option not available on the R3000j and R3000h-NA)

Off

(default)

UPS will supply utility power if the utility voltage is within ±20% of the nominal voltage. If the utility voltage is outside this range, the UPS will supply battery power.

5

Wiring

On

Enables an audio alarm if ground is

 

Fault

(default)

missing, or if line and neutral connections

 

 

 

have been reversed.

 

 

 

(This option not available on the R3000j

 

 

 

and R3000h-NA)

 

 

 

 

 

 

Off

Disables the audio alarm for this event.

 

 

 

(Default for R3000j and R3000h-NA)

 

 

 

 

6

Low

On

Enables an audio alarm 3 minutes before

 

Battery

(default)

battery shutdown.

 

 

 

 

 

 

Off

Enables an audio alarm 5 minutes before

 

 

 

battery shutdown.

continued

Page 50
Image 50
Compaq 3000 Series manual Configuration Parameters/LED Indicators, Explanation