Table 10: lpfc Dynamic Parameters (Do not require a driver reload to change) (Continued)

Variable

Default

Min

Max

Comments

 

 

 

 

 

 

 

 

 

 

lpfc_use_adisc

0

0=Off

1=On

Sends ADISC instead of

 

 

 

 

PLOGI for device discovery or RSCN.

 

 

 

 

 

Driver for VMware ESX Configuration Parameters

All HBA-specific parameters have an lpfcX_ prefix (where X is the driver instance number); e.g., setting lpfc0_lun_queue_depth= 20 makes 20 the default number of maximum commands which can be sent to a single logical unit (disk) for lpfc instance 0.

Dynamic parameters do not require the driver to be unloaded and reloaded for changes to take effect.

Table 11: Driver for VMware ESX Configuration Parameters

Variable

Default

Min

Max

Dynamic

Comments

 

 

 

 

 

 

 

 

 

 

 

 

lpfc_hba_queue_depth

8192

0

8192

Yes

Maximum number of FCP

 

 

 

 

 

commands that can queue to an

 

 

 

 

 

Emulex HBA.

 

 

 

 

 

 

lpfc_initiator_login

0

0

1

Yes

Enables logins to other virtual

 

 

 

 

 

initiators.

 

 

 

 

 

 

lpfc_ack0

0

0=Off

1=On

No

Use ACK0 for class 2.

 

 

 

 

 

 

lpfc_automap

1

0=Off

1=On

No

Automatically assign SCSI IDs to

 

 

 

 

 

FCP targets detected.

 

 

 

 

 

 

lpfc_check_cond_err

0

0=Off

1=On

Yes

Treat certain FCP check conditions

 

 

 

 

 

as FCP RSP errors.

 

 

 

 

 

 

lpfc_cr_count

1

1

255

No

This parameter determines the

 

 

 

 

 

values for I/O coalescing for

 

 

 

 

 

cr_delay (msec) or cr_count

 

 

 

 

 

outstanding commands.

 

 

 

 

 

 

lpfc_cr_delay

0

0

63

No

This parameter determines the

 

 

 

 

 

values for I/O coalescing for

 

 

 

 

 

cr_delay (msec) or cr_count

 

 

 

 

 

outstanding commands.

 

 

 

 

 

 

lpfc_delay_rsp_err

0

0=Off

1=On

Yes

Treat FCP RSP errors like no-

 

 

 

 

 

device-delay.

 

 

 

 

 

 

lpfc_discovery_threads

1

30

64

No

Specifies the maximum number of

 

 

 

 

 

ELS commands that can be

 

 

 

 

 

outstanding for a discovery.

 

 

 

 

 

 

lpfc_dqfull_throttle_up_inc

1

0

128

Yes

Amount to increment LUN queue

 

 

 

 

 

depth each time.

 

 

 

 

 

 

lpfc_dqfull_throttle_up_tim

1

0

30

Yes

Time interval, in seconds, to

e

 

 

 

 

increment LUN queue depth.

 

 

 

 

 

 

lpfc_extra_io_tmo

0

0

255

Yes

Extra FCP cmd timeout when

 

 

 

 

 

connected to a fabric (in seconds).

 

 

 

 

 

 

The HBAnyware Utility User Manual

Page 92

Page 97
Image 97
Emulex 3.4 user manual Driver for VMware ESX Configuration Parameters, Variable Default Min Max Dynamic Comments