HBAnyware Security Configurator Situations - Backup Masters

Table 20: HBAnyware Security Configurator - Backup Masters Situations

Situation

Resolution

 

 

 

 

Cannot create a backup master.

Select a system (or group of systems) from the MSC to be

 

the Backup Master. The system must be either an

 

unsecured system (which will be secured by being made a

 

Backup Master), or a system that is not part of any ASG

 

(client or server). These systems will mirror the MSC's

 

security configuration.

 

Because the Backup Master may some day take over as

 

the MSC, the Backup Master must be able to physically

 

access all of the systems that the MSC can access.

 

Therefore, if the MSC is connected to multiple fabrics, the

 

Backup Master also must be connected to those same

 

fabrics. When you select a Backup Master, the HBAnyware

 

Security Configurator displays a warning if it detects that

 

the system selected to be a Backup Master is not able to

 

physically access the same systems that the MSC can

 

access.

 

 

Cannot modify the Security Configurator.

Select a system (or group of systems) from the MSC to be

 

the Backup Master. The system must be either an

 

unsecured system (which will be secured by being made a

 

Backup Master), or a system that is not part of any ASG

 

(client or server). These systems will mirror the MSC's

 

security configuration.

 

The Backup Master has client access from the HBAnyware

 

utility to all of the servers in the MSC's ACG. However, the

 

Backup Master does not have client access to the MSC and

 

it cannot modify the security configuration (create, modify or

 

delete ASGs).

 

 

No Backup Master and the MSC is no longer

The servers are no longer part of a valid security

available. I do not have a Backup Master and the

configuration because there is no MSC to provide master

MSC system is no longer available. The servers

control of the configuration. In order to reset the security on

are still secure. I installed the Security

the affected servers, you must contact Emulex Technical

Configurator on another system, but I cannot

Support to receive a special application and instructions on

access those servers to remove the security from

the reset procedure. After the servers have been reset, they

them.

should be seen by the Security Configurator and the

 

HBAnyware utility. At this point, you can set up security

 

again through another MSC. At this time, also create a

 

Backup Master.

 

 

The Backup Master tab is not available.

The Backup Master tab is displayed only when the Security

 

Configurator is running on the MSC or a Backup Master.

 

You use this tab to set up a system or systems to be

 

backups to the MSC and to replace the MSC with a Backup

 

Master.

 

Each time you start the Security Configurator on the MSC

 

and there is no Backup Master assigned, a warning

 

message urges you to assign at least one Backup Master to

 

prevent the loss of security information if the MSC were to

 

become disabled.

 

 