Displaying PCI Registers and Wakeup Information
A PCI Register dump for the selected HBA appears in the lower left panel of the Diagnostics tab. Wakeup information for the selected HBA appears in the lower right panel of the Diagnostics tab. The information is
Figure 56: PCI Registers and Wakeup Parameters Area of the Diagnostics tab
Running Advanced Diagnostic Tests
The Advanced Diagnostics feature gives you greater control than the Quick Test over the type of diagnostics tests that run. Through Advanced Diagnostics, you can specify which tests to run, the number of cycles to run and what to do in the event of a test failure.
To run advanced diagnostics tests:
Click Advanced Diagnostics Test on the Diagnostics tab to view the Advanced Diagnostics dialog box. You can run four types of tests:
•PCI Loopback
•Internal Loopback
•External Loopback
•
Note: You cannot run the External Loopback test and ECHO test concurrently. If you select External Loopback the ECHO test section is disabled and vice versa.
The HBAnyware Utility User Manual | Page 118 |