
Figure 34: Driver Parameters tab - Host Selected
5.Enter a new value in the Value field in decimal or hexadecimal format, depending on how the current value is presented. If the value is in hexadecimal format, it is prefaced by "0x" (for example” 0x2d”).
6.To make a change temporary (the parameter to revert to its last permanent setting when the system is rebooted), check the Make changes temporary box. This option is available only for dynamic parameters.
7.To make changes to multiple parameters, check the Make all changes temporary box. Only dynamic parameters can be made temporary.
8.Click Apply.
Changing Non-dynamic Parameter Values (Linux)
To change
1.Navigate to the /usr/sbin/hbanyware directory and run the scripts to stop the HBAnyware utility processes. Type:
./stop_hbanyware
2.Stop all I/O to LPFC attached devices.
3.Unload the lpfcdfc driver. Type: rmmod lpfcdfc
4.Unload the LPFC driver. Type: rmmod lpfc
5.Reload the driver.Type:
modprobe lpfc modprobe lpfcdfc
The HBAnyware services will start automatically when you launch the application. For these changes to persist after a reboot you must create a new ramdisk image.
The HBAnyware Utility User Manual | Page 51 |