Master Security Client Situations
Table 22: Master Security Client Situations
| Situation | Resolution | 
| 
 | 
 | 
| 
 | 
 | 
| The MSC is no longer bootable or able to | You must reassign a Backup Master as the new MSC | 
| connect to the FC network. | from the Backup Master. | 
| 
 | Warning: Use this procedure only if the MSC cannot | 
| 
 | relinquish control to a Backup Master. For | 
| 
 | example, if the MSC is no longer bootable or | 
| 
 | able to connect to the FC network. Under any | 
| 
 | other circumstances, if the Backup Master | 
| 
 | takes over as the MSC and the MSC is still | 
| 
 | running or comes back online later, there will | 
| 
 | be two MSCs for the same security | 
| 
 | configuration. This will eventually lead to | 
| 
 | corruption of the security configuration. | 
| 
 | 
 | 
| New Keys Were Generated While Servers Were | The servers are no longer part of the security | 
| Offline. A "Generate New Keys" operation was | configuration. In order to reset the security on the | 
| performed while one or more of the servers were | affected servers, you must contact Emulex Technical | 
| offline. Now those servers can no longer access the | Support to receive a special application and instructions | 
| HBAnyware Security Configurator or the | on the reset procedure. After the servers have been | 
| HBAnyware utility. | reset, they can be added back into the security topology | 
| 
 | by the MSC. | 
| 
 | Note: If the server was also a client to an ASG, then | 
| 
 | when you run the Security Configurator on the | 
| 
 | MSC or a parent client of this client, its label in the | 
| 
 | ASG tree of the Access  | 
| 
 | ASG (Offline Client)  | 
| 
 | (after deleting the child ASGs) and recreate the | 
| 
 | ASG configuration of this client and its child | 
| 
 | ASGs. | 
| 
 | 
 | 
| Security Removed While Servers Were Offline. | The servers are no longer part of the security | 
| Security was removed while one or more servers | configuration. In order to reset the security on the | 
| were offline. I can no longer access those servers | affected servers, contact Emulex Technical Support to | 
| from the Security Configurator or the HBAnyware | receive a special application and instructions on the | 
| utility. | reset procedure. After the servers have been reset, they | 
| 
 | should be seen by the Security Configurator or the | 
| 
 | HBAnyware utility. | 
| 
 | 
 | 
| The HBAnyware Utility User Manual | Page 147 | 