Appendix III TCP/IP Configuration

Appendix II Firmware Recovery

This section demonstrates how to reload the firmware to the access point should the system fail to launch properly. In such cases, the access point will automatically switch to loader mode and the DIAG LED will light up and remain ON.

Table 1 below illustrates the behaviour of the DIAG LED.

Operation State

DIAG LED

Corrupted firmware – The access point switches to loader mode

Recovery in progress

Successful recovery

Blinks very fast

ON

Blinks very slowly

AII

How to recover the access point from failed firmware

Before starting, check the status of the DIAG LED against Table 1 above to verify whether firmware failure has occurred.

9.Power the access point off and disconnect it from the network.

10.Use a MDI cable (cross-connect for the access point) to connect the LAN port of the access point to the LAN port of your computer.

11.Power the access point on, and then start up your computer. The computer will obtain an IP address of 192.168.168.100 from the access point.

12.Insert the access point Product CD into the CD drive of your computer.

13.From the computer, click Start, then Run and type in the following command:

X:TFTP -i 192.168.168.1 PUT X:image_name.IMG, where X refers to your CD drive and image_name.IMG to the firmware filename found in the Recovery folder of the Product CD.

14.If you have downloaded a newer firmware and have saved it in your local hard disk as for example, C:\accesspoint\accesspointxxxx.IMG, then replace X:\image_name.IMG with this new path and firmware name.

15.The recovery process will now take place. You can check the DIAG LED against Table 1 to monitor the progress of the recovery process.

16.When firmware restoration has completed, reboot the access point and it will be ready to operate.

122

Page 123
Image 123
Compex Technologies WPE54 manual Operation State, Diag LED