CY7C1380C

CY7C1382C

3.3V TAP AC Test Conditions

2.5V TAP AC Test Conditions

Input pulse levels

VSS to 3.3V

Input rise and fall times

1ns

Input timing reference levels

1.5V

Output reference levels

1.5V

Test load termination supply voltage

1.5V

Input pulse levels

VSS to 2.5V

Input rise and fall time

1ns

Input timing reference levels

1.25V

Output reference levels

1.25V

Test load termination supply voltage

........1.25V

3.3V TAP AC Output Load Equivalent

2.5V TAP AC Output Load Equivalent

 

 

 

 

 

 

1.5V

 

 

 

 

 

1.25V

 

 

 

 

 

 

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

50

TDO

 

 

 

 

 

 

 

 

 

 

 

 

 

TDO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZO= 50

 

 

 

 

 

 

 

20pF

 

 

 

ZO= 50

 

 

 

 

 

 

 

20pF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TAP DC Electrical Characteristics And Operating Conditions (0°C < TA < +70°C; Vdd = 3.3V ±0.165V unless otherwise noted)[11]

PARAMETER

DESCRIPTION

TEST CONDITIONS

MIN

MAX

UNITS

 

 

 

 

 

 

VOH1

Output HIGH Voltage

IOH = -4.0 mA,VDDQ = 3.3V

2.4

 

V

 

 

IOH = -1.0 mA,VDDQ = 2.5V

2.0

 

V

VOH2

Output HIGH Voltage

IOH = -100 µA

VDDQ = 3.3V

2.9

 

V

 

 

 

VDDQ = 2.5V

2.1

 

V

VOL1

Output LOW Voltage

IOL = 8.0 mA

VDDQ = 3.3V

 

0.4

V

 

 

 

VDDQ = 2.5V

 

0.4

V

VOL2

Output LOW Voltage

IOL = 100 µA

VDDQ = 3.3V

 

0.2

V

 

 

 

VDDQ = 2.5V

 

0.2

V

VIH

Input HIGH Voltage

 

VDDQ = 3.3V

2.0

VDD + 0.3

V

 

 

 

VDDQ = 2.5V

1.7

VDD + 0.3

V

VIL

Input LOW Voltage

 

VDDQ = 3.3V

-0.3

0.8

V

 

 

 

VDDQ = 2.5V

-0.3

0.7

V

IX

Input Load Current

GND < VIN < VDDQ

 

-5

5

µA

Note:

11. All voltages referenced to VSS (GND).

Document #: 38-05237 Rev. *D

Page 18 of 36

[+] Feedback