D-Link DES-3624 manual Monitoring, Switch Overview, 33. Switch Statistics window

Models: DES-3624

1 162
Download 162 pages 15.63 Kb
Page 134
Image 134
Monitoring

Stackable NWay Ethernet Switch User’s Guide

Monitoring

This third main category of the Switch Web-based management program includes: Switch Overview, Port Utilization, Port Traffic Statistics, Port Error Packet Statistics, Port Packet Analysis Statistics, Browse Address Table, Browse IGMP Status, and Switch History.

Switch Overview

Figure 7-33. Switch Statistics window

The information is described as follows:

Update Interval Choose the desired setting: 5 seconds, 15 seconds, 30 seconds, 60 seconds or Suspend.

Port The selected port to be monitored.

TX frames/sec Counts the total number of frames transmitted from a selected port per second since the Switch was last rebooted.

RX frames/sec Counts all valid frames received on the port per second since the Switch was last rebooted.

134

Web-Based Network Management

Page 134