REFERENCES

The message is sent in the following format:

"Message" CR LF5.3.3Reception Warning Message

The Master cradle can transmit warning messages to the Host regarding wrong reception of data. Example:

/*Two-Ways Out of Sequence!(.....)*/

This message is transmitted to the Host by the Master cradle when the Master cradle receives a closing string from the Host for a Two-way tx communication, but this was either not open or already closed, therefore the data will be lost. See par. 5.9.4.

5.3.4Master Header/Terminator Selection

In addition to the standard header/terminator selection, the Master cradle can add its own header/terminator to the entire message sent to the Host.

In the STAR-System™ network headers and terminators for all RF Devices are disabled by default.

The Master header and terminator default values are as follows depending on the interface selection towards the Host:

RS-232:

no header, terminator CR-LF

WEDGE:

no header, terminator ENTER

See par. 5.4.1 and 5.4.2.

 

5.4DATA FORMAT

For an overview of Message Formatting see Chapter 6.

5.4.1Header/Terminator Selection

The header/terminator selection is not effected by the reading of the restore default code. In fact, header and terminator default values depend on the interface selection:

RS-232:

no header, terminator CR-LF

WEDGE:

no header, terminator ENTER

145