Appendix A
Table 3. Printer Options Menu
Datamax Setting | Description | PTX Setting |
|
|
|
CUTTER | Used to cut media into | MEDIA CONTROL → Media |
| separate labels. | HandlingCut |
| ENABLED, *DISABLED, NOT |
|
| INSTALLED |
|
SCANNER | Used to check the bar codes | VALIDATOR menu |
| on the labels. |
|
GPIO PORT | Model dependant option used | GPIO CONTROL menu and |
| to interface the printer to an | GPIO Manager |
| external controlling device. |
|
|
|
|
| Table 4. System Settings Menu |
|
|
|
|
Datamax Setting | Description | PTX Setting |
|
|
|
CONFIGURATION FILE | Options for storage and recall |
|
| of printer configuration files. |
|
RESTORE AS CURRENT | Provides a list of available | CONFIG CONTROL → Load |
| configuration files. Selecting a | Config |
| file from the list causes a |
|
| printer reset; afterward, the |
|
| printer is configured |
|
| according to the activated file. |
|
SAVE SETTING AS | Saves the entire effective | CONFIG CONTROL → Save |
| configuration of the printer to | Config |
| a file. |
|
DELETE FILE | Provides a list of available | CONFIG CONTROL → |
| configuration files to delete. | Delete Config |
FACTORY SETTING FILE | The selected file will be | CONFIG CONTROL → |
| restored whenever a Level 1 | |
| reset is performed. |
|
INTERNAL MODULE | Sets the number of 1K blocks | N/A |
| allocated for the internal RAM |
|
| ‘D’ module. |
|
| *1024 KB |
|
DEFAULT MODULE | Sets the default module used | PPI/DGL SETUP → Default |
| to store files when no other | Module |
| module is specified.*D | *RAM, Flash |
|
|
|
48