Ticket Exit

The printed tickets are expelled from this opening.

Darkness Control

The Darkness Control will adjust the darkness of the printing on the tickets: turning the control clockwise darkens the print and turning the control counterclockwise lightens the print. This darkness function can also be controlled through software commands.

Indicators

For a brief period (approximately 20 seconds) after power-up, all three indicators will remain on while the printer performs internal diagnostics.

POWER: Turning ‘On’ the power switch lights this indicator.

FAULT: During normal operation, this indicator will flash briefly as the printer receives data from the host system; however, if a fault is detected this indicator stays on. A fault can have several different causes; see Section 5 for details.

ON-LINE:In the on-line mode, this indicator lights to denote that the printer is ready to accept data. Pressing the PAUSE button while tickets remain to print causes the indicator to flash repeatedly. This indicator remains off in the off-line mode.

Dual-Purpose Buttons

Depending upon the printer’s mode, the buttons function as follows:

On-Line Mode Button Functions (the On-Line Indicator is ‘On’)

PAUSE: Press this to temporarily stop printing (pause mode) or to enter the off-line mode.

Press this button in pause mode to resume printing from the point stopped; or, if in off-line mode press to return to the on-line mode.

FEED: Press this button to advance the ticket stock to the next print position.

TEST: This button is inactive in the on-line mode.

ST/SV-3210 and ST/SV-3306

15

Page 25
Image 25
Datamax ST-3210, SV-3306, ST-3306, SV-3210 manual Ticket Exit