7DEOH0HVVDJH&￿￿￿&RQILJXUDWLRQ8WLOLW\3UREDEOH0HVVDJHV&DXVH￿FRQWLQXHG￿ &RUUHFWLYH$FWLRQ

The ICU detects

a resource conflict between this card and conflicting_card.The con- flicting resource was: resource.

You added or modified a card that now requires a resource value already in use by conflicting_card.

Try each of the following options until the problem is resolved:

Modify the card you are adding so that it uses a different value for resource. See “Modifying a Card” in Chapter 4 for instructions.

Modify conflicting_card so that it uses a different value for resource. See “Modifying a Card” in Chapter 4 for instructions.

If conflicting_card is not the system board or riser board, remove it from the computer. See “Removing a Card” in Chapter 4 for instructions.

Remove all expansion cards from the ICU, and then add them back one at a time, beginning with the new card and resolving resource conflicts as they arise. See “Removing a Card” and “Adding a Listed Card” or “Adding an Unlisted Card” in Chapter 4 for instructions.

If you cannot resolve the resource conflict by any of the preceding methods, remove the new card. If you were modifying an existing card, reset the modified card to its previous resource value.

NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary.

C-4Dell Precision 610 Mini Tower Systems User’s Guide

Page 172
Image 172
Dell manual 4Dell Precision 610 Mini Tower Systems User’s Guide