Power supply
X-STREAM XEGC
24 VDC is supplied to the unit by means of a
three-pin XLR connector on the rear panel of
the instrument.
Depending on the order, the following is sup-
plied as an accessory: either
• an external power supply unit which can
be connected directly to the analyzer using
the supplied cable
or
• a connector which can be used with a
cable and PSU as specied by the cu-
stomer.
Note the conguration of the pins on the con-
nector ( Fig. 4-14).
Fig. 4-14: 24 V DC in Connector, Pin Conguration
1: ME
2: + 24 V
3: 0 V (⊥)
2 1 3
Details of any PSUs supplied with the unit are
given on 2-9.