Emerson Process Management GmbH & Co. OHG9-50
X-STREAM XE
Instruction Manual
HASXEE-IM-HS
04/2010
9.4 List of Parameters and Registers - Sorted by Daniel Registers
Address Tag Name Data
Type
Client
Access Description
Daniel Modicon
9486 6971…
6972
Service.Measurement.Simulation.
SimPVARawValue1 Float R/W simulation value for rawPVA of comp1
9487 6973…
6974
Service.Measurement.Simulation.
SimPVARawValue2 Float R/W simulation value for rawPVA of comp2
9488 6975…
6976
Service.Measurement.Simulation.
SimPVARawValue3 Float R/W simulation value for rawPVA of comp3
9489 6977…
6978
Service.Measurement.Simulation.
SimPVARawValue4 Float R/W simulation value for rawPVA of comp4
9490 6979…
6980
Service.Measurement.Simulation.
SimPVARawValue5 Float R/W simulation value for rawPVA of comp5
9591 7181…
7182
Service.Measurement.Lin.MinVa-
lue1 Float RO Linearizer Minimum Value of comp1
9592 7183…
7184
Service.Measurement.Lin.MaxVa-
lue1 Float RO Linearizer Maximum Value of comp1
9593 7185…
7186 Service.Measurement.Lin.CutOff1 Float R/W Linearizer Cut-off value of comp1
9691 7381…
7382
Service.Measurement.Lin.MinVa-
lue2 Float RO Linearizer Minimum Value of comp2
9692 7383…
7384
Service.Measurement.Lin.MaxVa-
lue2 Float RO Linearizer Maximum Value of comp2
9693 7385…
7386 Service.Measurement.Lin.CutOff2 Float R/W Linearizer Cut-off value of comp1
9791 7581…
7582
Service.Measurement.Lin.MinVa-
lue3 Float RO Linearizer Minimum Value of comp3
9792 7583…
7584
Service.Measurement.Lin.MaxVa-
lue3 Float RO Linearizer Maximum Value of comp3
9793 7585…
7586 Service.Measurement.Lin.CutOff3 Float R/W Linearizer Cut-off value of comp1
9891 7781…
7782
Service.Measurement.Lin.MinVa-
lue4 Float RO Linearizer Minimum Value of comp4
9892 7783…
7784
Service.Measurement.Lin.MaxVa-
lue4 Float RO Linearizer Maximum Value of comp4
9893 7785…
7786 Service.Measurement.Lin.CutOff4 Float R/W Linearizer Cut-off value of comp1
9991 7981…
7982
Service.Measurement.Lin.MinVa-
lue5 Float RO Linearizer Minimum Value of comp5
9992 7983…
7984
Service.Measurement.Lin.MaxVa-
lue5 Float RO Linearizer Maximum Value of comp5
9993 7985…
7986 Service.Measurement.Lin.CutOff5 Float R/W Linearizer Cut-off value of comp1
3012…
3015
3012…
3015
Setup.Display.Component.PV_Unit-
String1 String R/W unit displayed for comp1
3017…
3020
3017…
3020
Setup.Display.Component.PV_Unit-
String2 String R/W unit displayed for comp2
3022…
3025
3022…
3025
Setup.Display.Component.PV_Unit-
String3 String R/W unit displayed for comp3
3027…
3030
3027…
3030
Setup.Display.Component.PV_Unit-
String4 String R/W unit displayed for comp4