Emerson Process Management GmbH & Co. OHG 7-11
X-STREAM XE
Instruction Manual
HASXEE-IM-HS
10/2010
7Maintenance & Procedures
7.4.1 Preparing a Calibration
Before starting to assign valves to gases and
channels, you need to check if valves are
supported:
Open SETUP - INSTALLED OPTIONS and
check the "Valves:" line.
Available options:
None: Valves are not supported
Internal: Open INTSHS ( 7-12) to assign
internal valves.
External: Open DIGITAL OUTPUTS (
7-13) to assign external valves.
Int+Ext: Open both, INTSHS ( 7-120)
and DIGITAL OUTPUTS ( 7-12) to assign
internal and external valves.
Installed Options 1of2
Licenses..
Valves: None
Pumps: None
XDIO1 Installed: No
XDIO2 Installed: No
Anal. Outputs: 4
AIN Installed: No