9Modbus Commands
9.4 List of Parameters and Registers - Sorted by Daniel Registers
Address Tag Name Data
Type
Client
Access Description
Daniel Modicon
3032…
3035
3032…
3035
Setup.Display.Component.PV_Unit-
String5 String R/W unit displayed for comp5
3041…
3045
3041…
3045 Setup.Display.Component.Tag1 String R/W displayed tag for component1
3046…
3050
3046…
3050 Setup.Display.Component.Tag2 String R/W displayed tag for component2
3051…
3055
3051…
3055 Setup.Display.Component.Tag3 String R/W displayed tag for component3
3056…
3060
3056…
3060 Setup.Display.Component.Tag4 String R/W displayed tag for component4
3061…
3065
3061…
3065 Setup.Display.Component.Tag5 String R/W displayed tag for component5
3071…
3074
3071…
3074
Setup.Display.Component.Gasna-
me1 String R/W gas name of component1
3075…
3078
3075…
3078
Setup.Display.Component.Gasna-
me2 String R/W gas name of component2
3079…
3082
3079…
3082
Setup.Display.Component.Gasna-
me3 String R/W gas name of component3
3083…
3086
3083…
3086
Setup.Display.Component.Gasna-
me4 String R/W gas name of component4
3087…
3090
3087…
3090
Setup.Display.Component.Gasna-
me5 String R/W gas name of component5
3101…
3104
3101…
3104
Setup.Display.MeasDisplay.Dis1La-
bel1 String R/W displayed label of measure display 1, Line 1
3105…
3108
3105…
3108
Setup.Display.MeasDisplay.Dis1La-
bel2 String R/W displayed label of measure display 1, Line 2
3109…
3112
3109…
3112
Setup.Display.MeasDisplay.Dis1La-
bel3 String R/W displayed label of measure display 1, Line 3
3113…
3116
3113…
3116
Setup.Display.MeasDisplay.Dis1La-
bel4 String R/W displayed label of measure display 1, Line 4
3117…
3120
3117…
3120
Setup.Display.MeasDisplay.Dis1La-
bel5 String R/W displayed label of measure display 1, Line 5
3121…
3124
3121…
3124
Setup.Display.MeasDisplay.Dis2La-
bel1 String R/W displayed label of measure display 2, Line 1
3125…
3128
3125…
3128
Setup.Display.MeasDisplay.Dis2La-
bel2 String R/W displayed label of measure display 2, Line 2
3129…
3132
3129…
3132
Setup.Display.MeasDisplay.Dis2La-
bel3 String R/W displayed label of measure display 2, Line 3
3133…
3136
3133…
3136
Setup.Display.MeasDisplay.Dis2La-
bel4 String R/W displayed label of measure display 2, Line 4
3137…
3140
3137…
3140
Setup.Display.MeasDisplay.Dis2La-
bel5 String R/W displayed label of measure display 2, Line 5
3141…
3147
3141…
3147 Info.SerialNumber String RO serial number of the device
3251…
3266
3251…
3266
Service.General.Identication.
ManufacturingInfo String RO Infos stored for manufacturing purposes
3461…
3468
3461…
3468
Service.Measurement.Simulation.
SimXSPMuxEnable1 Word R/W enable simulation for XSP‘s multiplexer value1..8