INSTALLATION (All VSM 301-701 Models)

Service

INSTALLATION (All VSM 301-701 Models)

A)

Install the gate rotor support. Carefully tilt the

 

roller bearing end of the gate rotor support to-

 

wards the suction end of the compressor. The

 

compressor input shaft may have to be rotated

 

to facilitate the installation of the gate rotor

 

support.

B)

Install the roller bearing housing with a new

 

O-ring. Tighten the bolts to the recommended

 

torque value.

C)

Install the spindle with shims and o-ring, tighten

 

the bolts to the recommended torque value,

 

measure the clearance between the shelf and

 

blade.

D)

Check the clearance between the entire gate

 

rotor blade and the shelf, rotate the gate rotor

 

to find the tightest spot. It should be between

Gaterotor for C-flange Models

0.003”-0.004”. Make adjustments, if necessary.

It is preferable to shim the gate rotor blade

 

 

looser rather than tighter against the shelf.

E)

Once the clearance is set remove the spindle.

 

Install new o-ring, apply Loctite 242 thread

 

locker to the socket head cap screw clamping

 

the thrust bearings to the spindle. Torque all

 

bolts to the recommended torque values.

F)

Install side covers with new gaskets. Tighten

 

bolts to the recommended torque value. The

 

unit can now be evacuated and leak checked as

 

outlined in section 0.03.