World Class 3000

Instruction Manual

Appendix A Rev. 3.8

July 2002

A

CONNECTIONSUPPLYAIRREFERENCEBITE TYPE FITTING (PARKER CPI) FOR MAX.PSIG3ATSCFH2TUBING.O.D.0.250 CLEAN DRY AIR REQUIRED. FITTING SIDE.FARONLOCATEDIS

CONNECTION.GASPURGEANDCALIBRATIONBITE TYPE FITTING (PARKER CPI) CALIBRATIONMAX.PSIG32ATSCFH10GAS REQUIRED.

DOESTEMPERATUREGASENSURETOLAG NOT GO BELOW DEW POINT OR 500EXCEED

VERTICALLYAINANALYZERWITHINSTALLDOWNWARDS DIRECTION ONLY.

RANGETEMPERATUREOPERATINGGASFLUE 1200

 

 

 

 

 

 

 

.C)

 

 

 

 

 

 

 

o

 

 

 

 

 

 

 

980

 

 

 

 

 

 

 

TO

 

 

 

 

 

 

 

o

 

 

 

 

 

 

 

(650

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

o

 

 

 

 

 

 

 

1800

 

 

 

 

 

 

 

TO

 

 

 

 

 

 

 

o

 

 

 

 

C.

 

 

 

 

 

 

 

 

o

 

 

 

 

1.

 

2.

3.

 

4.

5.

NOTES:

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

20 FT

CABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STD

(6.1 M)

 

 

 

 

 

 

 

 

INSULATION.THKINCHTWORECOMMENDED6. THERMAL CONDUCTIVITY K

INSULATION.FOR0.5EQUALS

7.DIMENSIONSAREININCHESWITHMILLIMETERSINPARENTHESES.01

 

GROUP NOTE

FLANGE

HARDWAREANDGASKET06

C 9 FT (2743.2) GAS TUBE PICK-UP

MOUNTINGOPTIONAL

05

SUPPLIEDFLANGE150#

CUSTOMERBY

ANDGASKET

HARDWARE

 

1

4.026

A-AVIEW(102.26)

I.D.

62.50(1587.5) REF (4507C26G03) DIRECTION

(673.1)26.50REF (4507C26G01 AND G02)

 

 

 

 

 

UP-PICK

UP-PICK

 

CAL GAS

 

 

 

 

 

 

 

 

 

FLOWOF

 

 

 

 

 

TUBE GAS (914.4) FT

TUBE GAS (1828.8) FT

 

 

2

CABLE ELECT

 

 

 

REF

AIR

 

04 03

 

 

 

 

 

 

 

3

6

 

 

 

 

 

 

 

 

 

 

 

02

 

 

 

 

 

 

 

A

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ARRANGEMENT,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DRAIN

 

 

 

27.31 (693.67) CLEARANCE REQ

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FORPROBE

INSERTION

AND REMOVAL

 

 

 

 

 

3

6

 

19.80 (502.92)

FOR

3D3947G01

 

 

 

 

27270017

(4507C26G01)

 

 

 

30.62 (777.75) REF

(1854.2) REF (4507C26G02)

(2768.6) REF (4507C26G03)

(939.8) REF (4507C26G01)

 

 

 

 

73.00

109.00

37.00

 

 

 

 

 

6.0 (152.4) REF

6.50 (165.1) REF

IF EQUIPPED WITH THE OPTIONAL CERAMIC DIFFUSOR ASSEMBLY, PROBE ASSEMBLY MUST BE ORIENTED SO THAT VEE SHIELD IS SQUARE TO GAS FLOW.

 

 

 

 

Figure A-15. Bypass Probe Option (Sheet 1 of 3)

Rosemount Analytical Inc. A Division of Emerson Process Management

Appendices A-9

Page 107
Image 107
Emerson Process Management 3000 instruction manual Figure A-15. Bypass Probe Option Sheet 1

3000 specifications

Emerson Process Management is a key player in the field of industrial automation, and one of its flagship offerings is the Emerson Process Management 3000. This system is designed to optimize production processes across a variety of industries, enhancing efficiency and ensuring robust operational performance.

One of the main features of the Emerson Process Management 3000 is its advanced control capabilities. The system employs model predictive control (MPC) technology, which allows for real-time data processing and decision-making. By predicting future trends in process variables, the MPC enables operators to adjust control parameters proactively, minimizing fluctuations and improving overall productivity.

Additionally, the Emerson 3000 integrates seamlessly with existing industrial infrastructure. This system supports a wide range of communication protocols, ensuring compatibility across various devices and sensors. Its flexibility allows companies to leverage their investment in existing technologies while upgrading to more modern control strategies.

The user interface of the Emerson Process Management 3000 is highly intuitive, featuring graphical displays that provide operators with clear visibility into process parameters. This interface is designed for ease of use, with customizable dashboards that can be tailored to meet the specific needs of the users. Training time is significantly reduced due to the straightforward design, leading to quicker onboarding for new operators.

In terms of data analytics, the Emerson 3000 also stands out. It features built-in data logging and trend analysis capabilities, empowering operators to make informed decisions based on historical and real-time data. This analytical strength helps in identifying inefficiencies and potential areas for improvement, contributing to reduced downtime and lower operational costs.

Safety is another critical characteristic of the Emerson Process Management 3000. The system includes robust safety features and compliance with various industry standards. By integrating safety into the control process, it ensures that product quality and equipment integrity are maintained, thus safeguarding both personnel and assets.

Overall, Emerson Process Management 3000 is a sophisticated control system that combines advanced technologies, user-friendly design, and robust safety features. Ideal for industries such as oil and gas, chemicals, and water treatment, it is designed to enhance operational efficiency and drive productivity in modern industrial environments.