Instruction Manual

IB-106-300NH Rev. 4.2 July 2002

World Class 3000

2-Conductor T/C

(OPTIONAL)

 

 

 

 

 

 

Wire [150 Ft (45 m) Max]

 

 

 

 

(optional)

 

 

 

 

 

 

Line

Voltage

4 Twisted Pair Plus 2 Twisted Pair

 

 

 

 

 

 

 

 

for Options [1200 Ft (364 m) Max]

Stack Thermocouple

 

 

 

Line Voltage

(optional)

 

 

 

 

7-Conductor Cable

HPS 3000

 

 

[150 Ft (45 m) Max]

HPS 3000

 

 

 

 

 

 

Explosion

Proof

 

 

 

Required

only for

 

 

 

Hazardous Area

 

 

 

Applications, otherwise

 

 

 

use NEMA 4X.

 

 

 

Lengths Exceeding

 

IFT 3000

 

150 ft (45 m).

 

 

 

 

World Class 3000

 

 

 

Intelligent Field Transmitter

 

 

 

NEMA 4X Enclosure

Probe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line

Voltage

 

 

 

 

 

 

 

 

100 to 120 Volt

 

 

 

 

(OPTIONAL)

 

 

 

220 to 240 Volt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line Voltage

 

 

 

 

 

 

MPS 3000

 

 

 

5 Conductor

 

 

 

 

 

 

 

2-Calibration Gas Lines

 

 

 

 

 

[1000 Ft (309 m) Max]

 

CALIBRATION GAS

 

 

 

by Customer

 

 

 

 

 

 

[300 Ft (90 m) Max]

 

 

SEQUENCER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Modular Design

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Up to 4 Probes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

Calibration Gas

 

 

 

 

 

 

 

 

by

 

 

 

 

 

 

 

Customer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(HPS not required for lengths of less than 150 feet)

World Class 3000

Probe

7-Conductor Cable

[150 Feet (45 m) Max]

Stack Thermocouple

2-Conductor T/C

(optional)

 

Wire [150 Feet (45 m) Max]

 

(optional)

2-Calibration Gas Lines by Customer

[300 Ft (90 m) Max]

IFT 3000

Intelligent Field Transmitter

NEMA 4X Enclosure

Line Voltage

100 to 120 Volt

220 to 240 Volt

HART Model 275

Hand Held

Interface

World Class 3000

Line Voltage

4-20 mA Output (Twisted Pair)

Probe

7-Conductor Cable

[150 Ft (45 m) Max]

Line Voltage

 

 

 

 

 

 

 

 

 

 

 

HPS 3000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IFT 3000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Termination in

 

 

 

 

 

 

 

 

 

 

 

Intelligent Field Transmitter

Control Room

 

 

 

 

 

 

 

 

Heater Power Supply

NEMA 4X Enclosure

[Optional,

 

 

 

 

Required for > 150 Ft (45 m)]

Line Voltage

 

100

to

120

Volt

 

220

to

240

Volt

4 Twisted Pair, plus 2 Twisted Pair for Options [1200 Ft (364 m) Max]

Customer's Laptop with Cornerstone Software

Customer's Distributed

Control System

with HART

Interface Capability

27270002

Figure 1-3. World Class 3000 Typical Application with Intelligent Field Transmitters

1-6 Description and Specifications

Rosemount Analytical Inc. A Division of Emerson Process Management

Page 30
Image 30
Emerson Process Management 3000 instruction manual Hps

3000 specifications

Emerson Process Management is a key player in the field of industrial automation, and one of its flagship offerings is the Emerson Process Management 3000. This system is designed to optimize production processes across a variety of industries, enhancing efficiency and ensuring robust operational performance.

One of the main features of the Emerson Process Management 3000 is its advanced control capabilities. The system employs model predictive control (MPC) technology, which allows for real-time data processing and decision-making. By predicting future trends in process variables, the MPC enables operators to adjust control parameters proactively, minimizing fluctuations and improving overall productivity.

Additionally, the Emerson 3000 integrates seamlessly with existing industrial infrastructure. This system supports a wide range of communication protocols, ensuring compatibility across various devices and sensors. Its flexibility allows companies to leverage their investment in existing technologies while upgrading to more modern control strategies.

The user interface of the Emerson Process Management 3000 is highly intuitive, featuring graphical displays that provide operators with clear visibility into process parameters. This interface is designed for ease of use, with customizable dashboards that can be tailored to meet the specific needs of the users. Training time is significantly reduced due to the straightforward design, leading to quicker onboarding for new operators.

In terms of data analytics, the Emerson 3000 also stands out. It features built-in data logging and trend analysis capabilities, empowering operators to make informed decisions based on historical and real-time data. This analytical strength helps in identifying inefficiencies and potential areas for improvement, contributing to reduced downtime and lower operational costs.

Safety is another critical characteristic of the Emerson Process Management 3000. The system includes robust safety features and compliance with various industry standards. By integrating safety into the control process, it ensures that product quality and equipment integrity are maintained, thus safeguarding both personnel and assets.

Overall, Emerson Process Management 3000 is a sophisticated control system that combines advanced technologies, user-friendly design, and robust safety features. Ideal for industries such as oil and gas, chemicals, and water treatment, it is designed to enhance operational efficiency and drive productivity in modern industrial environments.