Using LANVIEW
4-4 Troubleshooting
Amber
and off
Alternating (67% on, 33%
off). Indicates that a
shutdown process has
completed. This indication
will remain for 60 seconds
before automatically
restarting.
While in this state, you have 60 seconds
to safely remove the DFE-Gold module
from the chassis.
RX
(Receive)
None No link. No activity. Port
enabled or disabled.
None.
Green Solid. Link present, port
enabled, no traffic is being
received by the interface.
None.
Amber Flashing. Link present, port
enabled, traffic is being
received by the interface.
None.
Red Blinking. Indicates
collisions. This indication is
only supported on 10/100
ports.
Contact EnterasysNetworks for
technical support.
TX
(Transmit)
None Port enabled, but no activity. If it is known that the port should be
active and is not, contact
EnterasysNetworks for technical
support.
Green Flashing. Indicates data
transmission activity. Rate of
flashing indicates the data
rate.
None.
Red Flashing. Fault or Error
(collision).
None, unless there is a high rate of
activity. In this case, check for network
configuration problems or a defective
device.
Table 4-1 LANVIEW LEDs (continued)LED Color State Recommended Action