Using LANVIEW

Table 4‐1 describes the LED indications and provides recommended actions as appropriate.

The terms flashing, blinking, and solid used in Table 4-1indicate the following:

Flashing indicates an LED is flashing randomly.

Blinking indicates an LED is flashing at a steady rate (approximately 50% on, 50% off).

Solid indicates a steady LED light. No pulsing.

Alternating indicates an LED is flashing in a steady rate other than 50% on, 50% off.

Table 4-1 LANVIEW LEDs

LED

Color

State

Recommended Action

 

 

 

 

MGMT

None

Off. This module is NOT the

None.

 

 

Management Module.

 

 

 

 

 

 

Green

Solid. This module is the

None.

 

 

designated Management

 

 

 

Module.

 

 

 

 

 

 

Amber

Flashing. This is a

None.

 

 

temporary indication that the

 

 

 

module is saving data.

 

 

 

 

 

CPU

None

Power off.

Ensure chassis has adequate power.

 

 

 

 

 

Amber

Blinking. Module in process

None.

 

 

of booting.

 

 

 

 

 

 

 

Solid. Testing.

If the LED remains amber for several

 

 

 

minutes, contact Enterasys Networks

 

 

 

for technical support.

 

 

 

 

 

Green

Blinking. Image starts

None.

 

 

running.

 

 

 

 

 

 

 

Solid. Functional.

None.

 

 

 

 

 

Red

Solid. Processor in reset.

None.

 

 

 

 

 

Green

Blinking. Indicates that the

None. This state is activated when the

 

and

module is in the process of

OFFLINE/RESET switch is pressed for

 

Amber

shutting down.

less than 1 second to start the process

 

 

 

of an orderly shutdown.

 

 

 

While in this state, do not remove any

 

 

 

DFE-Gold module from the chassis.

Matrix DFE-Gold Series Installation Guide 4-3

Page 67
Image 67
Enterasys Networks 6H303-48, 4G4282-49, 9034096-02 manual Led, Color State Recommended Action