Viewing the Current Port Configuration

The Port Information screen displays the port type, status, link state, and flow control in use, as well as the communication speed and duplex mode. To change any of the port settings, use the Port Configuration menu. The parameters shown in the following figure and table are for the RJ-45 ports.

 

 

 

--Vertical Horizon Local Management VH-2402S

 

 

 

 

 

 

Port Information : Unit 1 Port 1-12

 

 

 

Port

 

Type

Operational Link

FlowControl

Speed and

 

 

 

 

 

 

 

InUse

Duplex InUse

 

 

-------------------------------------------------------------------------------------------------------

 

 

1.

10/100TX

YES

DOWN

-----------------

----------------

 

 

2.

10/100TX

YES

DOWN

-----------------

----------------

 

 

3.

10/100TX

YES

UP

802.3x

100-FULL

 

 

4.

10/100TX

YES

DOWN

-----------------

----------------

 

 

5.

10/100TX

YES

DOWN

-----------------

----------------

 

 

6.

10/100TX

YES

UP

NONE

100-HALF

 

 

7.

10/100TX

YES

UP

802.3x

100-FULL

 

 

8.

10/100TX

YES

UP

BACK_PRESSURE 10-FULL

 

 

9.

10/100TX

YES

UP

BACK_PRESSURE 10-FULL

 

 

10.

10/100TX

YES

UP

BACK_PRESSURE 10-FULL

 

 

11.

10/100TX

YES

UP

BACK_PRESSURE 10-FULL

 

 

12.

10/100TX

YES

UP

BACK_PRESSURE 10-FULL

 

 

<OK> <PREV Unit> <NEXT UNIT> <PREV PAGE> <NEXT PAGE>

 

 

 

 

Use <TAB> or arrows keys to move. <Enter> to select.

 

 

 

 

 

 

 

 

 

 

Figure 2-21. Port Information

 

 

 

 

 

 

 

 

Parameter

 

Description

 

 

 

Type

 

Shows port type as:

 

 

 

 

 

 

10/100TX

: 10Base-T / 100Base-TX

 

 

 

 

 

100FX

: 100Base-FX

 

 

 

 

 

1000SX : 1000Base-SX

 

 

 

 

 

1000LX

: 1000Base-LX

 

 

Operational

 

Shows if the port is functioning or not.

 

 

Link

 

Indicates if the port has a valid connection to an external device.

FlowControl InUse

Shows the flow control type in use. Flow control can eliminate

 

 

 

frame loss by “blocking” traffic from end stations connected

 

 

 

directly to the switch. Back pressure is used for half duplex and

 

 

 

IEEE 802.3x for full duplex. Note that flow control should not be

 

 

 

used if a port is connected to a hub.

 

 

Speed and

 

Displays the current port speed and duplex mode used.

DuplexInUse

 

 

 

 

 

 

 

30 VH-2402S User Interface

VH-2402S

Page 38
Image 38
Enterasys Networks VH-2402S manual Viewing the Current Port Configuration, Port Information