Printer Commands

Chapter 5

))))))))))))))))))))))))))))))))))))))))))))

^A ^D COMMAND

23Change SW3: Software dip switch #3. Below is the ^AB sequence:

12345678

^ABxxxxxxxx

*******. Not Used

******.Q Not Used

*****.)Q 1=Enable 460 Emulation, 0=Disable

****.))Q 1=Enable 450 Emulation, 0=Disable

***.)))Q 1=Enable Label Centering, 0=Disable **.))))Q 1=Send Response After a Print

**0=No Response After a Print

*.)))))Q Not Used

.))))))Q Not Used

Position:

1Always 0

2Always 0

3Response After Print: If enabled, an enquiry response will be sent back through the serial port after every print.

4Label Centering: The printer will center all label formats if this position is set to 1. Label centering creates an X offset for the older formats that were left justified. It will not center normal format fields on the label. It offsets a previously left justified label. Not recommended for new applications.

5450 Emulation: Only used if 450 format files are being sent to the printer.

6460 Emulation: Used if 460 format files are being sent to the printer.

7Always 0

8Always 0

))))))))))))))))))))))))))))))))))))))))))))

40

410 Operators Manual

Page 46
Image 46
Epson 410 manual Position Always