Chapter 5

Printer Commands

))))))))))))))))))))))))))))))))))))))))))))

5.3.4REAL-TIME CLOCK

^A ^D Command

30Change Clock: Use the sequence below to set the time and date of the optional real-time socket:

^D30 <CR> HH:MM:SS <CR> DD/MN/YR/W <CR>

Where the above parameters are defined as:

HH = hours (24 hour format) DD = day

MM = minutes

MN = month

SS = seconds

YR = last 2 of year

W = day of the week

1

= SUN

2

= MON

3

= TUE

4

= WED

5

= THR

6

= FRI

7

= SAT

The optional clock chip produces a string of data that is accessed through use of a TSN of 0 and a TSP dependent on the data required of the clock chip.

The data string is shown below...

HH:MM:SS MN/DD/YR XXX DD/MN/YR XXX

...where xxx is the day of the week.

These values should be inserted into the Field parameters for proper clock text access:

Clock Field Parameters

 

TSN

TSP

 

CC

DATA

 

 

0

1

 

8

HH:MM:SS

 

 

0

10

 

8

MN/DD/YR

 

 

0

19

 

3

Day of Week

 

 

0

23

 

8

DD/MN/YR

 

 

0

32

 

3

Day of Week

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 10

 

 

))))))))))))))))))))))))))))))))))))))))))))

410 Operators Manual

45

Page 51
Image 51
Epson 410 manual REAL-TIME Clock, D30 CR Hhmmss CR DD/MN/YR/W CR, = Sun, = Mon, = Tue, = Wed, = Thr, = Fri, = Sat