Epson 410 manual Auto-Size Label Section

Models: 410

1 104
Download 104 pages 24.81 Kb
Page 98
Image 98

Printer Commands

Chapter 5

))))))))))))))))))))))))))))))))))))))))))))

 

39

Auto-Size Label: Section 5.3.3.

 

0

Clears the use of auto-size values set by ^A1^D39.

 

1

Uses the values obtained for the variables instead of what the user supplies in the

2

header of the format file.

 

Automatically sizes the label and displays on the screen the values for the size

3

variables.

 

Same as ^A2^D39, but prints the values on a label, instead of on the screen.

40 Clear Commands 41-51.

XX41 Load number of fields in layout (HFM): Preceded by ^A.

XX

42

Load label width in dots (LXS): Preceded by ^A.

XX

43

Load label height in dots (LSY): Preceded by ^A.

XX

44

Load web size in dots (WEB): Preceded by ^A.

XX

45

Load gap size in dots (GAP): Preceded by ^A.

XX

46

Load print speed (DPS): Preceded by ^A.

XX

47

Load label control byte (LCB): Preceded by ^A.

XX

48

Load number of steps to activate gap detector (AGD): Preceded by ^A.

XX

49

Load number of steps past gap (SPG): Preceded by ^A.

XX

50

Load X direction offset (OFX): Preceded by ^A.

XX

51

Load Y direction offset (OFY): Preceded by ^A.

XX54 Send Saved Format File to Serial Port: ^A selection which one (1-8). Section 5.3.6.

XX55 Select ROM Label Layout: Select from the ROM power-up layouts. ^AXX ranges from 1 to 8.

56Select User Defined Layout: Signals to the printer the end of the label fields and precedes the text fields in a format file.

57Enter Label Format Mode: This tells the printer that information for a label is following.

XX58 Process Saved Format: ^A selects which one (1-8). Section 5.3.6.

XX59 Save Format File: ^A selects which one (1-8). Section 5.3.6.

))))))))))))))))))))))))))))))))))))))))))))

92

410 Operators Manual

Page 98
Image 98
Epson 410 manual Auto-Size Label Section