5-4Specifications

Electrical

 

120 V model

220/240 V model

 

 

 

Input voltage range

90 to 132 V

208 to 264 V

 

 

 

Rated frequency range

50 to 60 Hz

50 to 60 Hz

 

 

 

Input frequency range

49 to 61 Hz

49 to 61 Hz

 

 

 

Rated current

1.0 A

0.5 A

 

 

Power consumption

Approx. 100 W (ISO 10561 letter pattern)

 

30W or less in standby mode

 

 

 

This product is also designed for IT power systems with phase to phase voltage 220–240V. Check the label on the back of the printer for voltage information.

Initialization

Hardware initialization at power on:

The printer mechanism is set to its initial state.

The input data buffer and print buffer are cleared.

The printer returns to the last default settings.

Software initialization when the ESC@ (initialize the printer) command is received:

The print buffer is cleared.

The printer returns to the last default settings.

Panel button initialization by pressing the Pause button on the control panel for 3 seconds or more:

The print head is capped.

Any paper in the printer is ejected.

The input data buffer and print buffer are cleared.

The printer returns to the last default settings.

Safety Approvals

Safety standards

UL 1950, CSA 22.2 No. 950

EMC