| 120 V model | 220/240 V model |
|
|
|
Input voltage range | 90 to 132 V | 208 to 264 V |
|
|
|
Rated frequency range | 50 to 60 Hz | 50 to 60 Hz |
|
|
|
Input frequency range | 49 to 61 Hz | 49 to 61 Hz |
|
|
|
Rated current | 1.0 A | 0.5 A |
|
| |
Power consumption | Approx. 100 W (ISO 10561 letter pattern) | |
| 30W or less in standby mode | |
|
|
|
This product is also designed for IT power systems with phase to phase voltage
Hardware initialization at power on:
The printer mechanism is set to its initial state.
The input data buffer and print buffer are cleared.
The printer returns to the last default settings.
Software initialization when the ESC@ (initialize the printer) command is received:
The print buffer is cleared.
The printer returns to the last default settings.
Panel button initialization by pressing the Pause button on the control panel for 3 seconds or more:
The print head is capped.
Any paper in the printer is ejected.
The input data buffer and print buffer are cleared.
The printer returns to the last default settings.
Safety ApprovalsSafety standards | UL 1950, CSA 22.2 No. 950 |
EMC | FCC part 15 subpart B class B, CSA C108.8 class B |