CHAPTER 4: PERIPHERAL CIRCUITS AND OPERATION (Clock Timer)

4.8.4 I/O memory of clock timer

Table 4.8.4.1 shows the I/O addresses and the control bits for the clock timer.

 

 

 

 

 

 

 

 

Table 4.8.4.1

Control bits of clock timer

Address

 

 

Register

 

 

 

 

 

 

Comment

D3

 

D2

 

D1

D0

Name

Init 1

 

1

0

 

 

 

 

 

 

 

 

0

 

0

 

TMRST

TMRUN

0 3

2

 

 

 

Unused

 

 

 

 

0 3

2

 

 

 

Unused

FF78H

 

 

 

 

 

 

 

 

 

R

 

 

W

R/W

TMRST3

Reset

 

Reset

Invalid

Clock timer reset (writing)

 

 

 

 

 

 

 

 

 

TMRUN

0

 

Run

Stop

Clock timer Run/Stop

 

 

 

 

 

 

 

 

 

 

 

TM3

 

TM2

 

TM1

TM0

TM3

0

 

 

 

Clock timer data (16 Hz)

 

 

 

 

TM2

0

 

 

 

Clock timer data (32 Hz)

FF79H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

TM1

0

 

 

 

Clock timer data (64 Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TM0

0

 

 

 

Clock timer data (128 Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

TM7

 

TM6

 

TM5

TM4

TM7

0

 

 

 

Clock timer data (1 Hz)

 

 

 

 

TM6

0

 

 

 

Clock timer data (2 Hz)

FF7AH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

TM5

0

 

 

 

Clock timer data (4 Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TM4

0

 

 

 

Clock timer data (8 Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

EIT3

 

EIT2

 

EIT1

EIT0

EIT3

0

 

Enable

Mask

Interrupt mask register (Clock timer 1 Hz)

 

 

 

 

EIT2

0

 

Enable

Mask

Interrupt mask register (Clock timer 2 Hz)

FFE6H

 

 

 

 

 

 

 

 

 

 

 

 

R/W

 

EIT1

0

 

Enable

Mask

Interrupt mask register (Clock timer 8 Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

EIT0

0

 

Enable

Mask

Interrupt mask register (Clock timer 32 Hz)

 

 

 

 

 

 

 

 

 

 

 

IT3

 

IT2

 

IT1

IT0

IT3

0

 

(R)

(R)

Interrupt factor flag (Clock timer 1 Hz)

 

 

 

 

IT2

0

 

Yes

No

Interrupt factor flag (Clock timer 2 Hz)

FFF6H

 

 

 

 

 

 

 

 

 

 

 

 

R/W

 

IT1

0

 

(W)

(W)

Interrupt factor flag (Clock timer 8 Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

IT0

0

 

Reset

Invalid

Interrupt factor flag (Clock timer 32 Hz)

 

 

 

 

 

 

 

 

 

*1 Initial value at initial reset

*2 Not set in the circuit

*3 Constantly "0" when being read

TM0–TM7: Timer data (FF79H, FF7AH)

The 128–1 Hz timer data of the clock timer can be read out with these registers. These eight bits are read only, and writing operations are invalid.

By reading the low-order data (FF79H), the high-order data (FF7AH) is held until reading or for 0.48–1.5 msec (one of shorter of them).

At initial reset, the timer data is initialized to "00H".

TMRST: Clock timer reset (FF78H•D1)

This bit resets the clock timer.

When "1" is written: Clock timer reset

When "0" is written: No operation

Reading: Always "0"

The clock timer is reset by writing "1" to TMRST. When the clock timer is reset in the RUN status, operation restarts immediately. Also, in the STOP status the reset data is maintained. No operation results when "0" is written to TMRST.

This bit is write-only, and so is always "0" at reading.

TMRUN: Clock timer RUN/STOP control register (FF78H•D0)

Controls RUN/STOP of the clock timer.

When "1" is written: RUN

When "0" is written: STOP

Reading: Valid

The clock timer enters the RUN status when "1" is written to the TMRUN register, and the STOP status when "0" is written. In the STOP status, the timer data is maintained until the next RUN status or the timer is reset. Also, when the STOP status changes to the RUN status, the data that is maintained can be used for resuming the count.

At initial reset, this register is set to "0".