Troubleshooting

Note: A reset to factory default configuration cannot be undone. If you reset the Ericsson W3x to default configuration, all your previous configuration changes are replaced. If you have previously changed the password, the Enter password page will be displayed. You have to login to the web pages with the default password (user).

7.3

LAN Connections

 

 

Table 25 – LAN Connections

 

 

 

 

 

 

 

Indication/Symptom

What to do

 

 

 

 

 

 

Cannot access the local network

Check the network cable and make

 

 

from a PC that is connected to one

sure that there is a physical

 

 

of the Ethernet ports on the

connection between the PC and the

 

 

Ericsson W3x.

Ericsson W3x and that at least one

 

 

 

of the corresponding LAN

 

 

 

connector indicators is lit. If not,

 

 

 

make sure that the cable is properly

 

 

 

connected or try with another

 

 

 

Ethernet cable.

 

 

 

Check that the PC is configured to

 

 

 

obtain IP address automatically

 

 

 

using DHCP. If not, change the PC

 

 

 

TCP/IP settings. For instructions,

 

 

 

see section 6.1.1 – Obtaining IP

 

 

 

Settings Automatically or refer to

 

 

 

the manual of your operating

 

 

 

system.

 

 

 

 

 

 

Cannot access the WUI on the

Make sure you are using the

 

 

Ericsson W3x.

correct LAN IP address in the web

 

 

 

browser. If the LAN IP address has

 

 

 

been changed and you do not know

 

 

 

the current IP address, use the

 

 

 

Reset button to reset the Ericsson

 

 

 

W3x to factory default configuration

 

 

 

(see section 7.2). This will set the

 

 

 

LAN IP address to 192.168.1.1 and

 

 

 

the web page address to

 

 

 

http://mbr or http://192.168.1.1.

 

 

 

Make sure you are using the

 

 

 

correct login password. If the

 

 

 

default password has been

 

 

 

changed and you do not know the