Communication and Control, cont’d

At this point the driver is populated with unlearned functions. To learn driver functions:

1.Select those functions that are to be learned (see

figure 4-20). Then begin a learning session by pressing the learn toolbar button. A series of messages and windows will guide the user through the “learn” process, instructing the user on how to aim the remote, what button to press and when to release the button.

2.Save the driver by selecting File->Save, or you can add or learn new functions.

Figure 4-20 — Selecting driver functions

For more details about IR learning, refer to the IPL T IR Learner User’s Manual.

Programmer’s Guide for the Telnet and Web browser

Using the command/response table

The following are either Telnet (port 23) or Web browser (port

80)commands. There are some minor differences when implementing these commands via Telnet or via URL encoding using a Web browser. All commands listed below will work using either connection method, but due to some limitations of the Web browser, the encapsulation characters are modified to make sure that the Web browser will properly handle them. All examples in the command/response table shows the proper implementation in a Telnet or Web browser session.

For Web browsers: all non-alphanumeric characters must be represented as their hex equivalent such as %xx

where xx equals the two character representation of the hex byte that needs to be sent (e.g., a comma would be represented as %2C).

Telnet

Web Browser

Escape (Hex 1B)

W [must not be encoded]

Carriage Return (Hex 0D)

Pipe Character (

 

)

 

 

 

 

[must not be encoded]

When using these commands through a Web browser, the URL reference is used below to shorten the examples. This would in practice be the full URL of the control interface and Web page reference including all path information

(e.g., http://192.168.100.10/myform.htm).

To send any of the commands using a Web browser you need to prefix them with the full URL followed by ?cmd= See URL Encoding later in this chapter.

With Telnet you can use either the “Escape” commands or the “W” commands, and the carriage return or the pipe character. With the Web browser, you are required to use the “W” commands and the pipe character.

In either method {Data} = Data will be directed to a specified port and must be encoded if non-alphanumeric.

The table on pages 4-23 through 4-29 lists the commands that the IPL T interface recognizes as valid, the responses that are returned to the host, a description of the command’s function, or the results of executing the command.

Upper and lower case text can be used interchangeably except where noted.

Symbol definitions are shown below. An ASCII to HEX conversion table is also provided in figure 4-21 (below).

ASCII to HEX Conversion Table

Figure 4-21ASCII-to-HEX conversion table

4-16 IPL T SF24 and IPL T SFI244 • Communication and Control

IPL T SF24 and IPL T SFI244 • Communication and Control 4-17

Page 26
Image 26
Extron electronic IPL T SF24 Programmer’s Guide for the Telnet and Web browser, Using the command/response table