Fortinet 578 FortiWeb 5.0 Patch 6 Administration Guide
5. Click OK.
6. Group the email settings in a trigger (see “Configuring triggers” on page 557).
7. Add the appliance’s sender address (in the example above, fortiweb@example.com) to
your address book. Depending on your anti-spam software/device, you may also need to
adjust other settings to ensure that email from this appliance is not accidentally dropped or
tagged as spam.
8. To verify your settings and connectivity to the email server/relay, click Apply & Test.
See also
•Enabling log types, packet payload retention, & resource shortage alerts
•Configuring triggers
•Configuring alert email for event logs
Configuring alert email for event logsYou can configure FortiWeb to send an alert email for event log messages.
SMTP Username Type the user name of the account on the SMTP relay (e.g.
fortiweb) that will be used to send alerts.
This option is available only if Authentication is enabled.
SMTP Password Type the password of the account on the SMTP relay that will be used
to send alerts.
This option is available only if Authentication is enabled.
Log Level Select the priority threshold that log messages must meet or exceed
in order to cause an alert. For more information on log levels, see
“Log severity levels” on page 544.
Emergency Type the number of minutes between each alert if an alert condition of
severity level Emergency continues to occur after the initial alert.
Alert Type the number of minutes between each alert if an alert condition of
severity level Alert continues to occur after the initial alert.
Critical Type the number of minutes between each alert if an alert condition of
severity level Critical continues to occur after the initial alert.
Error Type the number of minutes between each alert if an alert condition of
severity level Error continues to occur after the initial alert.
Warning Type the number of minutes between each alert if an alert condition of
severity level Warning continues to occur after the initial alert.
Notification Type the number of minutes between each alert if an alert condition of
severity level Notification continues to occur after the initial alert.
Information Type the number of minutes between each alert if an alert condition of
severity level Information continues to occur after the initial alert.
Debug Type the number of minutes between each alert if an alert condition of
severity level Debug continues to occur after the initial alert.
Setting name Description