Franklin 2007 manual Pumptec-Plus Troubleshooting After Installation

Models: 2007

1 75
Download 75 pages 1.1 Kb
Page 65
Image 65

Maintenance – Electronic Products

Pumptec-Plus

Pumptec-Plus - Troubleshooting After Installation

SYMPTOM

POSSIBLE CAUSE

SOLUTION

 

 

Wait for the automatic restart timer to time out. During the time out period the well should

 

Dry Well

recover and fi ll with water. If the automatic reset timer is set to the manual position, then the

 

 

reset button must be pressed to reactivate the unit.

 

 

 

 

Blocked Intake

Clear or replace pump intake screen.

 

 

 

 

Blocked Discharge

Remove blockage in plumbing.

Solid Yellow Light

 

 

Check Valve Stuck

Replace check valve.

 

 

 

 

 

Broken Shaft

Replace broken parts.

 

 

 

 

Severe Rapid Cycling

Machine gun rapid cycling can cause an underload condition. See fl ashing red and yellow

 

lights section below.

 

 

 

 

 

 

Worn Pump

Replace worn pump parts and recalibrate.

 

 

 

 

Stalled Motor

Repair or replace motor. Pump may be sand or mud locked.

 

 

 

Yellow Flashing Light

Float Switch

A bobbing fl oat switch can cause two-wire motors to stall. Arrange plumbing to avoid

splashing water. Replace fl oat switch.

 

 

 

 

 

 

Ground Fault

Check insulation resistance on motor and control box cable.

 

 

 

 

Low Line Voltage

The line voltage is below 207 volts. Pumptec-Plus will try to restart the motor every two

 

minutes until line voltage is normal.

 

 

Solid Red Light

 

 

 

Check for excessive voltage drops in the system electrical connections (i.e. circuit breakers,

 

 

 

Loose Connections

fuse clips, pressure switch, and Pumptec-Plus L1 and L2 terminals).

 

 

Repair connections.

 

 

 

Flashing Red Light

High Line Voltage

The line voltage is over 253 volts. Check line voltage. Report high line voltage to the

power company.

 

 

 

 

 

 

 

The most common cause for the rapid cycle condition is a waterlogged tank. Check for a

 

Rapid Cycle

ruptured bladder in the water tank. Check the air volume control or snifter valve for proper

 

 

operation. Check setting on the pressure switch and examine for defects.

 

 

 

Flashing Red and

Leaky Well System

Replace damaged pipes or repair leaks.

 

 

Yellow Lights

Stuck Check Valve

Failed valve will not hold pressure. Replace valve.

 

 

 

 

 

 

Press and release the reset button to restart the unit. A bobbing fl oat switch may cause the

 

Float Switch

unit to detect a rapid cycle condition on any motor or an overload condition on 2-wire

 

 

motors. Try to reduce water splashing or use a different switch.

 

 

 