Fujitsu MCJ3230SS manual 75 Timing specifications 2 of, Timing Rule

Models: MCJ3230SS

1 161
Download 161 pages 59.65 Kb
Page 121
Image 121
4.5 Timing Rule

4.5 Timing Rule

Table 4.75 Timing specifications (2 of 3)

No.

Name

Standard

Timing specification

 

 

 

 

6

Bus Settle Delay

400 ns min.

Minimum wait period between the time a

 

 

 

particular control signal condition changes and

 

 

 

the time the bus condition is stabilized.

 

 

 

 

7

Cable Skew

10 ns max.

Maximum allowable difference in transmission

 

Delay

 

time over the interface cable between any two

 

 

 

bus signals from any two SCSI devices.

 

 

 

 

8

Data release

400 ns max.

Maximum allowable period between the time an

 

Delay

 

I/O signal changes its status from false to true

 

 

 

and the time the INIT stops driving data bus

 

 

 

signals.

 

 

 

 

9

Deskew Delay

45 ns min.

Time for compensation for skew involved in bus

 

 

 

signal transmission.

 

 

 

 

10

Hold Time

45 ns min.

In synchronous data transfer mode, the

 

 

 

minimum time during which the transfer data on

 

 

 

the DATA BUS from the leading edge of the

 

 

 

REQ or ACK signal pulse must be maintained to

 

 

 

compensate for the hold time in the SCSI device

 

 

 

receiving data.

 

 

 

 

11

Negation Period

90 ns min.

In synchronous data transfer mode, the

 

 

 

minimum time from the trailing edge of an REQ

 

 

 

signal to the leading edge of the next REQ

 

 

 

signal, or from the trailing edge of an ACK

 

 

 

signal to the leading edge of the next ACK

 

 

 

signal.

 

 

 

 

12

Power-On to

10 sec max.

Maximum time from when the TARG is turned

 

Selection Time

 

on to the time the TARG can post the correct

 

 

 

status and sense data for the TEST UNIT

 

 

 

READY, INQUIRY or REQUEST SENSE

 

 

 

command.

 

 

 

 

13

Reset to

250 ms max.

Maximum time from when the RESET condition

 

Selection Time

 

(hard RESET) is released to the time the TARG

 

 

 

can post the correct status and sense data for the

 

 

 

TEST UNIT READY, INQUIRY or REQUEST

 

 

 

SENSE command.

 

 

 

 

14

Reset Hold

25µs min.

The minimum time during which the RST signal

 

Time

 

must be held true to create a RESET condition.

 

 

 

A maximum time is not defined.

 

 

 

 

15

Selection Abort

200µs max.

In a SELECTION or RESELECTION phase, the

 

Time

 

maximum allowable period between the time the

 

 

 

SCSI device recognizes itself as selected and the

 

 

 

time it replies with a BSY signal.

 

 

 

 

C156-E224-01EN

4-47

Page 121
Image 121
Fujitsu MCJ3230SS manual 75 Timing specifications 2 of, Timing Rule