Installation Requirements

3.5 Settings

3.5.1 Default jumper settings

Figure 3.14 shows the types of switches and their settings when the drive was shipped.

Figure 3.14 Setting terminal (CNH2)

3.5.2Setting terminal

(1)SCSI ID

Table 3.5 shows the SCSI ID settings of the drive.

Table 3.5 SCSI ID setting (CNH2)

SCSI ID

Pin 5-6

Pin 3-4

Pin 1-2

 

 

 

 

0

Open

Open

Open

 

 

 

 

1

Open

Open

Short

 

 

 

 

2

Open

Short

Open

 

 

 

 

3

Open

Short

Short

 

 

 

 

4

Short

Open

Open

 

 

 

 

5

Short

Open

Short

 

 

 

 

6 *1

Short

Short

Open

 

 

 

 

7

Short

Short

Short

 

 

 

 

*1 Factory setting

3-18

C156-E224-01EN