Host Interface

Table 4.6 INQUIRY command response data

Bit

7

6

5

 

4

3

 

2

 

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Device classification code

 

 

Device Type

 

 

0

 

(000b)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"7Fh" when a value other than 0 is specified for LUN

 

 

 

 

 

 

 

 

 

 

 

 

 

1

RMB

 

 

 

 

Reserved

 

 

 

 

"1h"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

ISO Version "0h"

ECMA Version "0h"

 

ANSI Version "2h"

 

 

 

 

 

 

 

 

3

 

Reserved

 

 

Response data format (2h)

4

 

 

Additional length (2Bh)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-6

 

 

 

 

Reserved

 

 

 

 

7

RelAdr '0'

W Bus3

Wbus16

 

Sync '1'

Linked '0'

 

'0'

 

CmdQue

SftRe

 

 

2 '0'

'0'

 

 

 

 

 

 

'0'

'0'

 

 

 

 

 

Vendor Information

 

 

 

 

8-15

 

 

 

"FUJITSU" (in ASCII)

 

 

 

 

 

Left justified. The rightmost data area not used is padded with spaces. (20h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Information

 

 

 

 

16-31

 

 

"MCJ3230SS" (in ASCII)

 

 

 

 

 

Left justified. The rightmost data area not used is padded with spaces. (20h)

32-35

 

 

Firmware Revision Level

 

 

 

 

 

 

"0000"-"999z" (in ASCII)

 

 

 

 

 

 

 

 

 

 

 

36

 

 

Firmware Local Revision

 

 

 

 

 

 

 

 

00h-FFh (in HEX)

 

 

 

 

 

 

 

 

 

 

 

 

 

37

 

 

Boot Firmware Revision Level

 

 

 

 

 

 

00h-FFh (in HEX)

 

 

 

 

 

 

 

 

 

 

 

 

 

38-39

 

 

Signature "MO" (in ASCII)

 

 

 

 

40-47

 

 

 

 

Factory Information

 

 

 

 

The Factory Information is the data that is provided for use at the factory. The data value may vary depending on the device. Therefore, INIT should not have an expected value. Normally, return 0.

4-12

C156-E224-01EN

Page 86
Image 86
Fujitsu MCJ3230SS manual Inquiry command response data